1. Position the thermostat approximately 5 ft. above floor

level.

2. Do not position thermostat where it can be directly

affected by the unit’s discharge air stream.

3. Avoid external walls and drafts from windows and doors.

4. Avoid positioning near shelves and curtains as these

restrict air movement.

5. Avoid heat sources (direct sunlight, heaters, dimmer

switches, etc.)

CEILING OPENING: 

Before beginning the installation, in-

spect the unit location, test the strength of the unit
mountings 

(see “Mechanical Information” in this IOM)

. An

opening in the false ceiling will then have to be cut to the
following sizes:

Small Cabinet

23-1/4” x 23-1/4”

Medium Cabinet

33-7/8” x 33-7/8”

Large Cabinet

46 x 33-7/8”

A template for ceiling cut-out and rod positions can be found
with the Cassette unit.

NOTE: Make sure the ceiling grid is supported separately
from the Cassette. The ceiling must not be supported by
any part of the Cassette unit, fascia or any associated wir-
ing or pipe work.

The hanger bolts can now be installed (use 3/8 all thread
rod) at the centers shown below:

Prepare the installation guides by folding the metal bracket
by hand along the row of holes.

The Cassette can now be lifted onto the hanging rods and
leveled at the correct distance from the ceiling with the aid of
the installation guides as shown.

FOLDED GUIDE

NOTE:

 

If the ceiling is not level or even, it is important

that the Cassette is installed level to ensure correct
pump operation and to maintain fan clearances. Any
slight discrepancy between the Cassette and ceiling
will be taken up by the fascia foam seal.

Secure unit in position with locknuts and washers on either
side of the Cassette bracket. Ensure threaded rod does not
protrude more than 2” (dimension C) below the mounting
bracket.

The unit can now be piped up in accordance with good refrig-
eration and/or plumbing practices.

CONDENSATE PIPEWORK:

 The Cassette is supplied with

a 1/2" diameter flexible PVC hose for connection to copper
or plastic drain pipework. When installing the Cassette the
following points should be remembered:

1. Maximum pump lift is 18”.

2. The highest point in the condensate pipework should be

as close to the unit as possible. This prevents a large
volume of water draining back into the unit when it is
switched off.

INNER CASE INSULATION

OUTER CASE
INSULATION

CASSETTE CASE

FALSE CEILING

GUIDE IN
POSITION

CABINET

A

B

SMALL

19-1/2"

23"

MEDIUM

29-5/8"

31-1/2"

LARGE

29-5/8" 43-11/16"

Содержание WLCA

Страница 1: ...ions CAF4 in 8 000 to 36 000 Btuh capacities and depending on the model elec tric heat can also be factory fitted as an option Designed for low noise levels easy installation and maintenance and a sli...

Страница 2: ...the fresh air knockouts on the Cassette case It is usually advised that the fresh air volume is approximately 10 of the unit s pub lished maximum air flow SITE INSTALLATION UNPACKING The cassette fas...

Страница 3: ...by folding the metal bracket by hand along the row of holes The Cassette can now be lifted onto the hanging rods and leveled at the correct distance from the ceiling with the aid of the installation g...

Страница 4: ...installed with the EMI logo along the same edge of the unit as the electrical panel On units fitted with microprocessor controls orient the fascia with the dis play panel along the same edge of the u...

Страница 5: ...ssette and interconnecting pipework with dry nitrogen to a pressure of 150 PSIG Record the pressure over a pe riod of time a minimum period of 60 minutes should be suf ficient to detect any major leak...

Страница 6: ...RELEVANT OUTDOOR UNIT MANUAL AND IN ADDITION NOTE THE FOLLOWING 1 0 PRE START UP CHECKLIST 2 2 ON OFF WORKS 2 3 INDOOR UNIT THREE FANS SPEEDS AVAILABLE MICRO ONLY 2 4 VANE SWEEP FUNCTIONS 2 5 TIMER F...

Страница 7: ...4 SUCTION AT EM I CONDENSER 7 8 SUCTION AT EM I CONDENSER WIRE FRAMED PERIFRAME CAF 4 TECHNICAL DATA CABINET DIMENSIONS 8 12 18 20 33 36 HEIGHT 10 3 4 9 1 2 9 1 2 9 1 2 11 1 2 11 1 2 WIDTH 22 1 2 32...

Страница 8: ...EMI ENVIROMASTER COM ENVIROMASTERINTERNATIONALLLC 8 SMALL CABINET CAH 9 000 12 000 CAHW 9 000 ONLY CAF 8 000 12 000 CAF4 8 000 ONLY EMI CASSETTE DIMENSIONS...

Страница 9: ...000 24 000 CAHW 12 000 24 000 CAF 18 000 20 000 CAF4 12 000 20 000 CASSETTE DIMENSIONS INCHES SIZE A B C D E F G H J K L M N MEDIUM 11 37 37 1 32 32 2 5 3 9 33 LARGE 13 49 37 1 32 45 2 6 13 9 45 EMI...

Страница 10: ...connected by a 7 pin plug and socket The green On Off indicator will remain lit when the unit is running or will flash if heating or cooling is required but the compressor anti cycle timer is delayin...

Страница 11: ...ir vanes to oscillate when selected not applicable to all models OFF Switches the unit off in certain instances the fan may be subject to a 2 minute run on time to dissipate residual heat ON SEND Pres...

Страница 12: ...riday 1 Press CLK Timer twice Program highlights NOTE Display will stop flashing after 15 seconds 2 Select Program 1 by pressing or Program 1 and Start Time will flash 3 Press or to select and change...

Страница 13: ...from the unit by opening the 1 4 air bleed Re tighten the bleed screw once all air has been re moved 8 Repeat steps 1 4 above for all Cassettes in the same systems The Cassettes are now ready for the...

Страница 14: ...MUM PUMP LIFT EXCEEDED Check that the con densate pump head is no greater than 18 See installation section of this manual for more information BLOCKED KINKED CONDENSATE PIPE See section Wa ter Leaking...

Страница 15: ...perating pressures Check filter condition See maintenance instruc tions for more information CONDENSATE PUMP BLOCKED OR FAILED See sec tion Water Leaking From Unit COIL FREEZE UP Acoil freeze conditio...

Страница 16: ...TOR Check actuator by manu ally opening and closing valve replace if faulty FAULTY HEATER RELAY Check signals to relay and check action of relay contacts Replace relay or PCB if nec essary FANS WILL N...

Страница 17: ...al condensate tray support channels and pull the channels away from the condensate tray Pull thecondensatetraydownwardsawayfromthechas sis 3 Remove the electrical panel lid and disconnect the fan conn...

Страница 18: ...equired 1 Insert the screwdriver into the square hole until you hit bottom This will open the terminal block so that it will accept your wire s 2 Insert the stripped wire into the oval or round hole 3...

Страница 19: ...anes 4 14 Freeze Protection Thermostat DX Electro Mechanical Version only 15 Filter 16 Fascia Assembly 17 Receiver Microprocessor Version 18 Terminal Rail Relays Timer Micro Electro Mechanical Version...

Страница 20: ...2 Vane Motor Assembly 13 Filter 14 Fascia 15 Remote Handset 16 Control Box Lid 17 Control Box PCB 18 Control Box 19 Coil Bracket 20 Expansion Valve Enviromaster International LLC 5780 Success Drive Ro...

Отзывы: