EM12 User’s Manual
5. Description of Function Codes
63
Value
Function
Range (Corresponding to Pulse or Analog Output Range 0.0%~100.0%)
12
AI2
0V~10 V
13
AI3
0V~10 V
14
Length
0~ maximum set length
15
Count value
0 ~ maximum count value
16
Communication setting
0~32767
b6-03
Maximum FMP output frequency
Default
50.00 kHz
Setting Range
0.01 kHz ~50.00 kHz
If the FM terminal is used for pulse output, this parameter is used to set the maximum frequency of pulse output.
b6-04
AO1 offset coefficient
Default
0.0%
Setting Range
-100.0% ~100.0%
b6-05
AO1 gain
Default
1.00
Setting Range
-10.00~10.00
b6-06
AO2 offset coefficient
Default
0.0%
Setting Range
-100.0% ~100.0%
b6-07
AO2 gain
Default
1.00
Setting Range
-10.00~10.00
These parameters are used to correct the zero drift of analog output and the output amplitude deviation. They can also
be used to define the desired AO curve. If "b" represents zero offset, "k" represents gain, "Y" represents actual output,
and "X" represents standard output, the actual output is: Y = kX + b.
The zero offset coefficient 100% of AO1 and AO2 corresponds to 10 V (or 20 mA). The standard output refers to the
value corresponding to the analog output of 0 to 10 V (or 0 to 20 mA) with no zero offset or gain adjustment.
For example, if the analog output is used as the running frequency, and it is expected that the output is 8 V when the
frequency is 0 and 3 V at the maximum frequency, the gain shall be set to -0.50, and the zero offset shall be set to
80%.
5.8 Group b7: Virtual digital input (VDI)/digital output (VDO) terminals
b7-00
VDI1 function selection
Default
0
b7-01
VDI2 function selection
Default
0
b7-02
VDI3 function selection
Default
0
b7-03
VDI4 function selection
Default
0
b7-04
VDI5 function selection
Default
0
VDI1~ VDI5 have the same functions as DI terminals on the control board and can be used for digital input. For more
details, see description of b3-00 ~ b3-11.
b7-05
VDI state setting mode
Default
00000
Setting
Range
Unit's digit: VDI1.
0
Valid decided by state of VDOx
1
Valid decided by b7-06
Ten's digit: VDI2 0, 1 (same as VDI1)
Hundred's digit: VDI3. 0, 1 (same as VDI1)
Thousand's digit: VDI4. 0, 1 (same as VDI1)
Ten thousand's digit: VDI5. 0, 1 (same as VDI1)
Содержание EM12 Series
Страница 5: ......