5.Description of Function Codes
EM12 User's Manual
52
b3-15
DI1 ON delay time
Default
0.0s
Setting Range
0.0s~3000.0s
b3-16
DI1 OFF delay time
Default
0.0s
Setting Range
0.0s~3000.0s
b3-17
DI2 ON delay time
Default
0.0s
Setting Range
0.0s~3000.0s
b3-18
DI2 OFF delay time
Default
0.0s
Setting Range
0.0s~3000.0s
b3-19
DI3 ON delay time
Default
0.0s
Setting Range
0.0s~3000.0s
b3-20
DI3 OFF delay time
Default
0.0s
Setting Range
0.0s~3000.0s
b3-21
DI4 ON delay time
Default
0.0s
Setting Range
0.0s~3000.0s
b3-22
DI4 OFF delay time
Default
0.0s
Setting Range
0.0s~3000.0s
b3-23
DI5 ON delay time
Default
0.0s
Setting Range
0.0s~3000.0s
b3-24
DI5 OFF delay time
Default
0.0s
Setting Range
0.0s~3000.0s
These parameters are used to set the delay time of the frequency inverter when the status of DI terminals changes.
The DI1 to DI5 support the delay time function.
b3-25
DI valid selection 1
Default
00000
Setting
Range
Unit's digit: DI1 valid mode.
0
Low level valid
1
High level valid
Ten's digit: DI2 valid mode.0, 1 (same as DI1)
Hundred's digit: DI3 valid mode.0, 1 (same as DI1)
Thousand's digit: DI4 valid mode.0, 1 (same as DI1)
Ten thousand's digit: DI5 valid mode.0, 1 (same as DI1)
b3-26
DI valid selection 2
Default
00000
Setting
Range
Unit's digit: DI1 valid mode.
0
Low level valid
1
High level valid
Ten's digit: DI2 valid mode.0, 1 (same as DI1)
Hundred's digit: DI3 valid mode.0, 1 (same as DI1)
Thousand's digit: DI4 valid mode.0, 1 (same as DI1)
Ten thousand's digit: DI5 valid mode.0, 1 (same as DI1)
These parameters are used to set the valid mode of DI terminals.
0: Low level valid
The DI terminal is invalid when being connected with COM, and valid when being disconnected from COM.
1: High level valid
The DI terminal is valid when being connected with COM, and invalid when being disconnected from COM.
5.5 Group b4: Output Terminals
The EM12 provides an analog output (AO) terminal, a digital output (DO) terminal, two relay terminal and a FM
Содержание EM12 Series
Страница 5: ......