EM12 User’s Manual
Appendix II
151
Code
Parameter Name
Setting range
Default
Property
C2-00 Simple PLC running mode
0: Stop after the Frequency inverter runs one cycle
1: Keep final values after the frequency inverter runs
one cycle
2: Repeat after the frequency inverter runs one cycle
0
☆
C2-01
Simple PLC record
selection
Unit's digit: Record of power failure.
0: no record after power off
1: record after power off
Ten's digit: Record of stopping.
0: no record after stopping
1:record after stopping
00
☆
C2-02
Running time of simple
PLC Segment 0
0.0s(h)~6553.5s(h)
0.0s (h)
☆
C2-03
Acceleration/deceleration
time of simple PLC
Segment 0
0~3
0
☆
C2-04
Running time of simple
PLC Segment 1
0.0s(h)~6553.5s(h)
0.0s (h)
☆
C2-05
Acceleration/deceleration
time of simple PLC
Segment 1
0~3
0
☆
C2-06
Running time of simple
PLC Segment 2
0.0s(h)~6553.5s(h)
0.0s (h)
☆
C2-07
Acceleration/deceleration
time of simple PLC
Segment 2
0~3
0
☆
C2-08
Running time of simple
PLC Segment 3
0.0s(h)~6553.5s(h)
0.0s (h)
☆
C2-09
Acceleration/deceleration
time of simple PLC
Segment 3
0~3
0
☆
C2-10
Running time of simple
PLC Segment 4
0.0s(h)~6553.5s(h)
0.0s (h)
☆
C2-11
Acceleration/deceleration
time of simple PLC
Segment 4
0~3
0
☆
C2-12
Running time of simple
PLC Segment 5
0.0s(h)~6553.5s(h)
0.0s (h)
☆
C2-13
Acceleration/deceleration
time of simple PLC
Segment 5
0~3
0
☆
C2-14
Running time of simple
PLC Segment 6
0.0s(h)~6553.5s(h)
0.0s (h)
☆
C2-15
Acceleration/deceleration
time of simple PLC
Segment 6
0~3
0
☆
C2-16
Running time of simple
PLC Segment 7
0.0s(h)~6553.5s(h)
0.0s (h)
☆
C2-17 Acceleration/deceleration 0~3
0
☆