EM12 User’s Manual
Appendix II
141
Code
Parameter Name
Setting range
Default
Property
b7-05 VDI state setting mode
Unit's digit: VDI1.
0: Valid decided by state of VDOx
1: Valid decided by b7-06
Ten's digit: VDI2.
0, 1 (same as VDI1)
Hundred's digit: VDI3.
0, 1 (same as VDI1)
Thousand's digit: VDI4.
0, 1 (same as VDI1)
Ten thousand's digit: VDI5.
0, 1 (same as VDI1)
00000
☆
b7-06 VDI state setting
Unit's digit: VDI1.
0: Invalid
1: Valid
Ten's digit: VDI2
0, 1 (same as VDI1)
Hundred's digit: VDI3
0, 1 (same as VDI1)
Thousand's digit: VDI4
0, 1 (same as VDI1)
Ten thousand's digit: VDI5.
0, 1 (same as VDI1)
00000
☆
b7-07
Function selection for AI1
used as DI
0~49
0
★
b7-08
Function selection for AI2
used as DI
0~49
0
★
b7-09
Function selection for AI3
used as DI
0~49
0
★
b7-10
Valid state selection for AI
used as DI
Unit's digit: AI1.
0: High level valid
1: Low level valid
Ten's digit: AI2.
0, 1 (same as unit's digit)
Hundred's digit: AI3.
0, 1 (same as unit's digit)
0
☆
b7-11 VDO1 function selection
0: connect with physical DIx internally
1~40
0
☆
b7-12 VDO2 function selection
0: connect with physical DIx internally
1~40
0
☆
b7-13 VDO3 function selection
0: connect with physical Dix internally
1~40
0
☆
b7-14 VDO4 function selection
0:connect with physical Dix internally
1~40
0
☆
b7-15 VDO5 function selection
0: connect with physical Dix internally
1~40
0
☆
b7-16 VDO1 output delay
0.0s~3000.0s
0.0s
☆
b7-17 VDO2 output delay
0.0s~3000.0s
0.0s
☆