Appendix II
EM12 User’s Manual
136
Code
Parameter Name
Setting range
Default
Property
b4-03
Relay 2 function
(TA2-TB2-TC2)
stop)
10: Reverse running
11: Zero-speed running (no output at stop)
12: Zero-speed running 2 (having output at stop)
13: Preset count value reached
14: Designated count value reached
15: Length reached
16: PLC cycle complete
17: Frequency-level detection FDT1 output
18: Frequency level detection FDT2 output
19: Frequency reached
20: Frequency 1 reached
21: Frequency 2 reached
22: Current 1 reached
23: Current 2 reached
24: Module temperature reached
25: Timing reached
26: Zero current state
27: Output current exceeded limitation
28: Lower voltage state output
29: Frequency inverter overload pre-warning
30: Motor overheat pre-warning
31: Motor overload pre-warning
32: off load
33: AI1 larger than AI2
34: AI1 input exceeded limitation
35: Alarm output (all faults)
36: Present running time reached
37: Accumulative power-on time reached
38: Accumulative running time reached
0
☆
b4-04
DO1 function selection
(open-collector output
terminal)
2
☆
b4-05 DO2 function(extend)
0
☆
b4-06 DO3 function(extend)
0
☆
b4-07 DO4 function(extend)
0
☆
b4-08 DO5 function(extend)
0
☆
b4-09 DO6 function(extend)
0
☆
b4-10 FMR ON delay time
0.0s~3000.0s
0.0s
☆
b4-11 FMR OFF delay time
0.0s~3000.0s
0.0s
☆
b4-12 Relay 1 ON delay time
0.0s~3000.0s
0.0s
☆
b4-13 Relay 1 OFF delay time
0.0s~3000.0s
0.0s
☆
b4-14 Relay 2 ON delay time
0.0s~3000.0s
0.0s
☆
b4-15 Relay 2 OFF delay time
0.0s~3000.0s
0.0s
☆
b4-16 DO1 ON delay time
0.0s~3000.0s
0.0s
☆
b4-17 DO1 OFF delay time
0.0s~3000.0s
0.0s
☆
b4-18 DO2 ON delay time
0.0s~3000.0s
0.0s
☆
b4-19 DO2 OFF delay time
0.0s~3000.0s
0.0s
☆