Safety
Information
Introduction
Product
Information
System
configuration
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running
the motor
Optimization
SMARTCARD
operation
Onboard
PLC
Advanced
parameters
Technical
Data
Diagnostics
UL Listing
Information
240
Unidrive SPM User Guide
www.controltechniques.com Issue Number: 3
Figure 13-43 SM-I/O 24V Protected analog output logic diagram
SM-I/O 24V Protected parameters
0.XX
0.XX
Key
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
The parameters are all shown at their default settings
T12 Analog output 2
T10 Analog output 1
10
Parameter
Range(
Ú
)
Default(
Ö
)
Type
x.01
Solutions Module ID
0 to 599
205
RO
Uni
PT
US
x.02
Solutions Module Main Software Version
0.00 to 99.99
RO
Uni
NC
PT
x.03
T5 digital I/O 3 state
OFF (0) or On (1)
RO
Bit
NC
PT
x.04
T6 digital I/O 4 state
OFF (0) or On (1)
RO
Bit
NC
PT
x.05
T7 digital input 5 state
OFF (0) or On (1)
RO
Bit
NC
PT
x.06
T8 digital input 6 state
OFF (0) or On (1)
RO
Bit
NC
PT
x.07
T9 digital input 7 state
OFF (0) or On (1)
RO
Bit
NC
PT
x.08
Relay 1 state
OFF (0) or On (1)
RO
Bit
NC
PT
x.09
T3 digital I/O 1 state
OFF (0) or On (1)
RO
Bit
NC
PT
x.10
T4 digital I/O 2 state
OFF (0) or On (1)
RO
Bit
NC
PT
x.11
T3 digital I/O 1 invert
OFF (0) or On (1)
OFF (0)
RW
Bit
US
x.12
T4 digital I/O 2 invert
OFF (0) or On (1)
OFF (0)
RW
Bit
US
x.13
T5 digital I/O 3 invert
OFF (0) or On (1)
OFF (0)
RW
Bit
US
x.14
T6 digital I/O 4 invert
OFF (0) or On (1)
OFF (0)
RW
Bit
US
x.15
T7 digital input 5 invert
OFF (0) or On (1)
OFF (0)
RW
Bit
US
x.16
T8 digital input 6 invert
OFF (0) or On (1)
OFF (0)
RW
Bit
US
x.17
T9 digital input 7 invert
OFF (0) or On (1)
OFF (0)
RW
Bit
US
x.18
Relay 1 invert
OFF (0) or On (1)
OFF (0)
RW
Bit
US
x.20
Digital I/O read word
0 to 255
RO
Uni
NC
PT
x.21
T3 digital I/O 1 source/destination
Pr
0.00
to
Pr
21.51
Pr
0.00
RW
Uni
DE
US
x.22
T4 digital I/O 2 source/destination
Pr
0.00
to
Pr
21.51
Pr
0.00
RW
Uni
DE
US
x.23
T5 digital I/O 3 source/destination
Pr
0.00
to
Pr
21.51
Pr
0.00
RW
Uni
DE
US
x.24
T6 digital I/O 4 source/destination
Pr
0.00
to
Pr
21.51
Pr
0.00
RW
Uni
DE
US
x.25
T7 digital input 5 destination
Pr
0.00
to
Pr
21.51
Pr
0.00
RW
Uni
DE
US
x.26
T8 digital input 6 destination
Pr
0.00
to
Pr
21.51
Pr
0.00
RW
Uni
DE
US
x.27
T9 digital input 7 destination
Pr
0.00
to
Pr
21.51
Pr
0.00
RW
Uni
DE
US
x.28
Relay 1 source
Pr
0.00
to
Pr
21.51
Pr
0.00
RW
Uni
US
x.29
T6 digital I/O 4 output select
OFF (0) or On (1)
On (1)
RW
Bit
US
x.31
T3 digital I/O 1 output select
OFF (0) or On (1)
OFF (0)
RW
Bit
US
x.32
T4 digital I/O 2 output select
OFF (0) or On (1)
OFF (0)
RW
Bit
US
x.33
T5 digital I/O 3 output select
OFF (0) or On (1)
OFF (0)
RW
Bit
US
x.39
Analog output mode
0-20, 20-0, 4-20, 20-4
0-20
RW
Uni
US
x.40
Relay 2 state
0.0 or 100.0 %
RO
Bit
NC
PT
x.42
Relay 2 invert
OFF (0) or On (1)
OFF (0)
RW
Bit
US
x.43
Relay 2 source
Pr
0.00
to
Pr
21.51
Pr
0.00
RW
Uni
US
x.45
Analog output 2 scaling
0.000 to 4.000
1.000
RW
Uni
US
x.47
Analog output 2 source
Pr
0.00
to
Pr
21.51
Pr
0.00
RW
Uni
US
x.48
Analog output 1 source
Pr
0.00
to
Pr
21.51
Pr
0.00
RW
Uni
US
x.49
Analog output 1 scaling
0.000 to 4.000
1.000
RW
Uni
US
x.50
Solutions Module error status
0 to 255
RO
Uni
NC
PT
x.51
Solutions Module software sub-version
0 to 99
RO
Uni
NC
PT