Safety
Information
Introduction
Product
Information
System
configuration
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running
the motor
Optimization
SMARTCARD
operation
Onboard
PLC
Advanced
parameters
Technical
Data
Diagnostics
UL Listing
Information
Unidrive SPM User Guide
243
Issue Number: 3 www.controltechniques.com
Figure 13-6 SM-I/O 32 logic diagram
SM-I/O 32 parameters
*See trip SLX.Er,
Automation (I/O Expansion) module category
on page 286.
X.XX
X.XX
Key
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
The parameters are all shown at their default setting
X.3y*
x(-1)
x(-1)
X.1y
X.0y**
I/O state
Output
select
S
ource/
destination
I/O invert
??.??
??.??
X.2y
Any unprotected
parameter
Parameter
Range(
Ú
)
Default(
Ö
)
Type
x.01
Solutions Module ID code
0 to 599
208
RO
Uni
PT
US
x.02
Solutions Module main software version
0.00 to 99.99
99.00
RO
Uni
NC
PT
x.03
Digital I/O 3 state
OFF(0) or On(1)
OFF (0)
RO
Bit
NC
PT
x.04
Digital I/O 4 state
OFF(0) or On(1)
OFF (0)
RO
Bit
NC
PT
x.05
Digital I/O 5 state
OFF(0) or On(1)
OFF (0)
RO
Bit
NC
PT
x.06
Digital I/O 6 state
OFF(0) or On(1)
OFF (0)
RO
Bit
NC
PT
x.07
Digital I/O 7 state
OFF(0) or On(1)
OFF (0)
RO
Bit
NC
PT
x.08
Digital I/O 8 state
OFF(0) or On(1)
OFF (0)
RO
Bit
NC
PT
x.09
Digital I/O 1 state
OFF(0) or On(1)
OFF (0)
RO
Bit
NC
PT
x.10
Digital I/O 2 state
OFF(0) or On(1)
OFF (0)
RO
Bit
NC
PT
x.11
Digital I/O 1 invert
OFF(0) or On(1)
OFF (0)
RW
Bit
US
x.12
Digital I/O 2 invert
OFF(0) or On(1)
OFF (0)
RW
Bit
US
x.13
Digital I/O 3 invert
OFF(0) or On(1)
OFF (0)
RW
Bit
US
x.14
Digital I/O 4 invert
OFF(0) or On(1)
OFF (0)
RW
Bit
US
x.15
Digital I/O 5 invert
OFF(0) or On(1)
OFF (0)
RW
Bit
US
x.16
Digital I/O 6 invert
OFF(0) or On(1)
OFF (0)
RW
Bit
US
x.17
Digital I/O 7 invert
OFF(0) or On(1)
OFF (0)
RW
Bit
US
x.18
Digital I/O 8 invert
OFF(0) or On(1)
OFF (0)
RW
Bit
US
x.20
Digital I/O read word
0 to 255
0
RO
Uni
NC
PT
x.21
Digital I/O 1 source/destination
Pr
0.00
to Pr
21.51
Pr
0.00
RW
Uni
DE
PT
US
x.22
Digital I/O 2 source/destination
Pr
0.00
to Pr
21.51
Pr
0.00
RW
Uni
DE
PT
US
x.23
Digital I/O 3 source/destination
Pr
0.00
to Pr
21.51
Pr
0.00
RW
Uni
DE
PT
US
x.24
Digital I/O 4 source/destination
Pr
0.00
to Pr
21.51
Pr
0.00
RW
Uni
DE
PT
US
x.25
Digital I/O 5 source/destination
Pr
0.00
to Pr
21.51
Pr
0.00
RW
Uni
DE
PT
US
x.26
Digital I/O 6 source/destination
Pr
0.00
to Pr
21.51
Pr
0.00
RW
Uni
DE
PT
US
x.27
Digital I/O 7 source/destination
Pr
0.00
to Pr
21.51
Pr
0.00
RW
Uni
DE
PT
US
x.28
Digital I/O 8 source/destination
Pr
0.00
to Pr
21.51
Pr
0.00
RW
Uni
DE
PT
US
x.29
Digital I/O 4 output select
OFF(0) or On(1)
On(1)
RW
Bit
PT
US
x.31
Digital I/O 1 output select
OFF(0) or On(1)
OFF (0)
RW
Bit
US
x.32
Digital I/O 2 output select
OFF(0) or On(1)
OFF (0)
RW
Bit
US
x.33
Digital I/O 3 output select
OFF(0) or On(1)
OFF (0)
RW
Bit
US
x.43
First update method direction register
Pr
0.00
to Pr
21.51
Pr
0.00
RW
Uni
DE
PT
US
x.47
Fast update method read register
Pr
0.00
to Pr
21.51
Pr
0.00
RW
Uni
DE
PT
US
x.48
Fast update method write register
Pr
0.00
to Pr
21.51
Pr
0.00
RW
Uni
PT
US
x.50
Solutions Module error status*
0 to 255
RO
Uni
NC
PT
x.51
Solutions Module software sub-version
0 to 99
RO
Uni
NC
PT
RW Read / Write
RO
Read only
Uni
Unipolar
Bi
Bi-polar
Bit
Bit parameter
Txt
Text string
FI
Filtered
DE
Destination
NC
Not copied
RA
Rating dependent
PT
Protected
US
User save
PS