6.14.1 SPMC Hardware configuration - Single
module
When a Unidrive SPMC is used to supply the DC Bus of SPMD, the
status output lines can be taken from the SPMC and feed directly into
the status inputs of the SPMD. The inverter will monitor the status lines
and on detection of a trip disable the system.
Figure 6-36 Single module control terminals and descriptions
75
74
Fan control
0V common
Single Module Rectifier
SPMC/U
73
72
Status input 0
0V common
71
Status input 1
0V common
85
84
External 24V
supply
0V common
83
82
Status output 0
0V common
81
80
Status output 1
0V common
60
61
62
63
Inverter (master)
SPMD
Status 0 input
0V common
Status 1 input
0V common
70
91
90
Relay contacts
Rectifier OK