Issue Number: 2 www.controltechniques.com
Table 3-3 575V Drive ratings (500V to 575V ±10%)
The power ratings above for model size 4 and larger are for the 690V drives when used on a 500V to 575V supply.
The above current ratings are given for max 40
°
C (104
°
F), and 3.0 kHz switching. Derating is required for higher switching frequencies, ambient
temperature >40
°
C (104
°
F) and high altitude. For further information, refer to both the
Unidrive SP and SPM User Guides
.
Model
Normal Duty
Heavy Duty
Maximum
continuous
output current
Nominal
power
at 575V
Motor
power
at 575V
Maximum
continuous
output current
Nominal
power
at 575V
Motor
power
at 575V
A
kW
hp
A
kW
hp
3501
5.4
3.0
3.0
4.1
2.2
2.0
3502
6.1
4.0
5.0
5.4
3.0
3.0
3503
8.4
5.5
7.5
6.1
4.0
5.0
3504
11
7.5
10
9.5
5.5
7.5
3505
16
11
15
12
7.5
10
3506
22
15
20
18
11
15
3507
27
18.5
25
22
15
20
4603
36
22
30
27
18.5
25
4604
43
30
40
36
22
30
4605
52
37
50
43
30
40
4606
62
45
60
52
37
50
5601
84
55
75
63
45
60
5602
99
75
100
85
55
75
6601
125
90
125
100
75
100
6602
144
110
150
125
90
125
1601
125
90
125
100
75
100
1602
144
110
150
125
90
125
1601
125
110
150
100
90
125
1602
144
132
175
125
110
150
1603
168
160
200
144
132
175
1604
192
185
250
168
160
200