A.6.8
Transient / built-in lightning protection
According to IEC 61000-4-5, level 2 kV line to ground. Complies with IEEE 587 Category B
transient protection and IEEE 472 surge protection.
A.6.9
Low Voltage Directive (LVD)
LVD (EU directive 2014/35/EU) EN/IEC 61010-1
A.7
Rosemount 5900C with parabolic antenna
Operating temperature in tank
Max. +180 °C (+356 °F) with FEP O-ring, or +230 °C (+445 °F) with Kalrez
®
O-ring
Measuring range
0.8 to 30 m (2.6 to 100 ft) below flange.
Possibility to measure 0.5 to 50 m (1.6 to 164 ft). Accuracy may be reduced. For longer
measuring range, consult your local representative.
Pressure range
Clamped/threaded: -0.2 to 0.2 bar (-2.9 to 2.9 psig)
Welded: -0.2 to 10 bar (-2.9 to 145 psig)
Material exposed to tank atmosphere
Antenna: Material corresponds to AISI 316/316L and EN 1.4401 /1.4404
Sealing: PTFE
O-ring: FEP, or Kalrez
®
Antenna dimension
440 mm (17 in.)
Manway size and installation
500 mm (20-in.) opening.
The parabolic antenna is installed on the manway cover by using the flange ball. It is
designed for easy adjustment of the antenna inclination and orientation within the
specified limits.
The flexible flange ball can be installed on both horizontal or inclined manways without
any special arrangements.
Tank connection
The gauge is clamped in a 96-mm (3.78-in.) diameter hole, or welded in a 117-mm (4.61-
in.) diameter hole.
Reference Manual
Specifications and reference data
00809-0100-5901
September 2019
Rosemount 5900C Radar Level Gauge
251
Содержание Rosemount 5900C
Страница 1: ...Reference Manual 00809 0100 5901 Rev DA September 2019 Rosemount 5900C Radar Level Gauge ...
Страница 6: ...Contents Reference Manual September 2019 00809 0100 5901 vi Reference Manual ...
Страница 12: ...Introduction Reference Manual September 2019 00809 0100 5901 12 Reference Manual ...
Страница 116: ...Installation Reference Manual September 2019 00809 0100 5901 116 Reference Manual ...
Страница 204: ...Configuration Reference Manual September 2019 00809 0100 5901 204 Reference Manual ...
Страница 208: ...Operation Reference Manual September 2019 00809 0100 5901 208 Reference Manual ...
Страница 244: ...Service and troubleshooting Reference Manual September 2019 00809 0100 5901 244 Reference Manual ...
Страница 278: ...Specifications and reference data Reference Manual September 2019 00809 0100 5901 278 Reference Manual ...
Страница 290: ...Product Certifications Reference Manual September 2019 00809 0100 5901 290 Reference Manual ...