Table 6-1: Troubleshooting Chart for the Rosemount 5900C
(continued)
Symptom
Possible cause
Action
Disturbing objects in the
tank
•
Check that the Rosemount 5900C has not locked on an
interfering object in the tank
•
Use the Tank Scan function in Rosemount TankMaster
WinSetup to analyze the measurement signal: - Check
if there are any disturbing echoes from obstacles in the
tank - Check if there is a strong echo at the bottom of
the tank; use deflection plate at the end of still pipe.
See the Rosemount Tank Gauging
for more information on how to
use the Tank Scan function
The level gauge
configuration can not be
saved
The gauge is write protected
•
Check position of the write protection switch and make
sure that it is in the OFF position, see
•
Check write protection setting in Rosemount
TankMaster WinSetup, see
.
6.3.1
Device status
shows device status messages that may appear on the display of the Rosemount
2410 Tank Hub, or in the Rosemount TankMaster program. Device status can be found in
Input register 4000. See
Viewing input and holding registers using TankMaster
for more
information on how to view Input registers.
Table 6-2: Device Status Messages
Message
Description
Action
Running Boot Software
•
The application software could not
be started.
•
The application SW is not loaded in
the flash memory
•
The previous upload of the flash
SW failed
Reprogram the gauge with new
software.
Contact Emerson Automation
Solutions /Rosemount Tank Gauging
service department.
Device Warning
A device warning is active.
Device Error
A device error is active.
for details.
BOOT Beta Version
Beta version of boot program used
Ensure that approved software is used
APPL Beta Version
Beta version of application program
used
Ensure that approved software is used
Level correction error
The LPG module is enabled but the
module is either incorrectly
configured, or there is no sensor input
data for pressure or temperature.
See Input register 4702 LPGIregArea-
LPG_Corr_Error for more information.
Reference Manual
Service and troubleshooting
00809-0100-5901
September 2019
Rosemount 5900C Radar Level Gauge
229
Содержание Rosemount 5900C
Страница 1: ...Reference Manual 00809 0100 5901 Rev DA September 2019 Rosemount 5900C Radar Level Gauge ...
Страница 6: ...Contents Reference Manual September 2019 00809 0100 5901 vi Reference Manual ...
Страница 12: ...Introduction Reference Manual September 2019 00809 0100 5901 12 Reference Manual ...
Страница 116: ...Installation Reference Manual September 2019 00809 0100 5901 116 Reference Manual ...
Страница 204: ...Configuration Reference Manual September 2019 00809 0100 5901 204 Reference Manual ...
Страница 208: ...Operation Reference Manual September 2019 00809 0100 5901 208 Reference Manual ...
Страница 244: ...Service and troubleshooting Reference Manual September 2019 00809 0100 5901 244 Reference Manual ...
Страница 278: ...Specifications and reference data Reference Manual September 2019 00809 0100 5901 278 Reference Manual ...
Страница 290: ...Product Certifications Reference Manual September 2019 00809 0100 5901 290 Reference Manual ...