Flange requirements
The Rosemount 5900C with Still-pipe Array Antenna fits flanges of size 5, 6, 8, 10 and 12
inch. The gauge has a flange for sealing the tank. The tank flange must be horizontal
within ±2°.
Figure 3-11: The Flange Must Be Horizontal Within ±2°
Recommended installation
When designing new tanks, an 8 inch still-pipe or larger is recommended. This is
particularly important in tanks with sticky and viscous products. See drawing
D9240041-917 “Recommended still-pipes” for more information on recommended still-
pipes for the Rosemount 5900C. Before manufacturing a new still-pipe, we recommend
that you contact Emerson Automation Solutions / Rosemount Tank Gauging for advice.
For highest performance, the total area of the slots or holes in the still-pipe must not
exceed the values shown in
below. The listed values refer to the total area of the
holes over the entire length of the pipe, regardless of its length. In some cases it is possible
to allow a larger total area than stated in
. When the limits are exceeded, please
contact Emerson Automation Solutions / Rosemount Tank Gauging for advice.
Table 3-7: Maximum Area of Slots and Holes
Pipe Dimension (inch)
Max. Area of Slots and Holes (m
2
)
5
0.1
6
0.1
8
0.4
10
0.8
12
1.2
Installation
Reference Manual
September 2019
00809-0100-5901
40
Reference Manual
Содержание Rosemount 5900C
Страница 1: ...Reference Manual 00809 0100 5901 Rev DA September 2019 Rosemount 5900C Radar Level Gauge ...
Страница 6: ...Contents Reference Manual September 2019 00809 0100 5901 vi Reference Manual ...
Страница 12: ...Introduction Reference Manual September 2019 00809 0100 5901 12 Reference Manual ...
Страница 116: ...Installation Reference Manual September 2019 00809 0100 5901 116 Reference Manual ...
Страница 204: ...Configuration Reference Manual September 2019 00809 0100 5901 204 Reference Manual ...
Страница 208: ...Operation Reference Manual September 2019 00809 0100 5901 208 Reference Manual ...
Страница 244: ...Service and troubleshooting Reference Manual September 2019 00809 0100 5901 244 Reference Manual ...
Страница 278: ...Specifications and reference data Reference Manual September 2019 00809 0100 5901 278 Reference Manual ...
Страница 290: ...Product Certifications Reference Manual September 2019 00809 0100 5901 290 Reference Manual ...