Table 2-2: Troubleshooting
(continued)
Error
Recommended action(s)
Flow temperature is
outside the alarm limits
•
Startup issues:
—
Verify that there is voltage to the temperature sensor from
either the meter's power supply board or from an external
power supply.
—
If using an analog pressure device, verify that the temperature
sensor is properly wired to the connector.
—
Verify the input is properly configured for your temperature
input.
—
If using a flow computer to write temperature to the meter,
verify that it is properly writing to fixed flow temperature in the
proper units.
•
Run time issues:
—
Adjust temperature of process fluid to within alarm limits.
—
If using an analog temperature device and input reading is 0,
check if
IsAI1Avail
is equal to 1 in the Meter Information dialog
in MeterLink. If it is not 1, either the I/O Board has been
removed or is damaged. Reinstall or replace the board if this
value is 0.
—
If using an analog temperature device, verify that the
temperature sensor is working properly.
—
If using an analog temperature device, recheck wiring and
switch settings.
—
If a flow computer is writing values to the fixed flow
temperature, verify that the flow computer is still writing valid
values without Modbus write errors.
—
Reverify the temperature input settings are correct.