4.3.2
Mounting on a pipe
To mount Rosemount 2240S on a pipe, do the following:
1. Use the four nuts to fasten the bracket on
a vertical pipe. A suitable pipe size is 1 to 2
inches.
2. Attach the Rosemount 2240S transmitter
to the bracket.
3. Secure the transmitter with the screw on
top of the bracket.
4. Proceed with electrical installation of
Tankbus, temperature elements, and
water level sensor. See
.
x4
Bracket
1 - 2 inches
Nuts
Bracket
Screw