122
Reference Manual
00809-0100-2240, Rev DA
October 2017
Table 6-4. Status registers for the Rosemount 2240S Multi-input Temperature Transmitter
Message
Description
Action
Device Status
Input register no. 100
(1)
.
Bit 1: Device warning
Bit 7: Device error
Bit 8: Simulation Mode Active
Bit 9: PTB Mode Active
Bit 10: PTB Resistance Out Of Limit
Bit 16: FF Block Out of Service (1.B0)
Bit 18: Device Write Protected
Bit 19: Factory setting used (default
database)
1.
The register number refers to the internal Input Register in the Rosemount 2240S database.
Contact Emerson Automation
Solutions/Rosemount TankGauging
service department for support.
Device error
Input register no. 102.
Bit 0: RAM Error
Bit 1: FPROM Error
Bit 2: HREG Error
Bit 3: SW Error
Bit 4: Other memory error
Bit 6: Reserved for Display error
Bit 7: Reserved for Modem error
Bit 9: Internal temperature error
Bit 10: Other HW error
Bit 11: Measurement Error
Bit 12: Configuration error
for
more information on the various error
types.
Contact Emerson Automation
Solutions/Rosemount TankGauging
service department for support.
Device warning
Input register no. 104.
Bit 0: RAM Warning
Bit 1: FPROM Warning
Bit 2: HREG Warning
Bit 3: SW Warning
Bit 4: Other memory warning
Bit 6: Reserved for Display warning
Bit 7: Reserved for Modem warning
Bit 9: Internal Temperature Warning
Bit 10: Other HW warning
Bit 11: Measurement warning
Bit 12: Config warning
for
more information on the various
warnings.
Contact Emerson Automation
Solutions/Rosemount TankGauging
service department for support.
Internal temp
Input register no. 106. Internal temperature.
Contact Emerson Automation
Solutions/Rosemount TankGauging
service department for support.
Internal temp
status
Input register no. 108.
Bit 0: Internal temperature out of limits
Bit 1: Temperature Device Error
Bit 15: Internal temperature not valid
MinIntTemp
Input register no. 110. Minimum measured
internal temperature.
MaxIntTemp
Input register no. 112. Maximum measured
internal temperature.
Содержание Rosemount 2240S
Страница 2: ......
Страница 10: ...viii Reference Manual 00809 0100 2240 Rev DA Title Page October 2017 Title Page ...
Страница 16: ...6 Reference Manual 00809 0100 2240 Rev DA Introduction October 2017 Introduction ...
Страница 28: ...18 Reference Manual 00809 0100 2240 Rev DA Overview October 2017 Overview ...
Страница 116: ...106 Reference Manual 00809 0100 2240 Rev DA Configuration Operation October 2017 Configuration Operation ...
Страница 150: ...140 Reference Manual 00809 0100 2240 Rev DA Service and Troubleshooting October 2017 Service and Troubleshooting ...
Страница 164: ...154 Product Certifications Product Certifications October 2017 Reference Manual 00809 0100 2240 Rev DA ...
Страница 192: ...182 Reference Manual 00809 0100 2240 Rev DA Index October 2017 Index ...
Страница 193: ......