contributor to spud distortion due to additional heat input and added filler material
in beveled area of hole.
Figure 3-32: Installing the Weld Spud
Preparing the vessel hole
Welding sequence
C
D
E
A
B
2.37
(60)
1
3
5
7
2
4
6
8
A. 100–125 A recommended
B. Heat isolation grooves
C. Weld spud
D. Bevelled edge
E. Process vessel
Dimensions are in inches (millimeters).
5. Remove the protective cover from the diaphragm of the remote seal. Use extreme
caution during installation to ensure the diaphragm is not damaged.
6. Place the gasket into the lower housing make sure the gasket is properly aligned on
the gasket sealing surface.
WARNING
Failure to properly install the gasket may cause process leaks, which can result in
death or serious injury.
7. Insert the UCP union connection seal into the lower housing and tighten the jam
nut.
CAUTION
Excessive heat will distort the weld spud. Allow adequate cooling time between
passes.
Installation
Reference Manual
May 2020
00809-0100-4002