Figure 3-23: Welding Sections
1
3
5
7
2
4
6
8
Allow time to cool between weld sections. Weld should be cooled to 350 °F (177 °C) or less
after each pass while being cool to the touch is preferred. Use of a damp cloth or
compressed air is allowed if rapid cooling is desired. Repeat procedure on the outside of
the tank.
Note
The number of weld passes should be kept to a minimum while maintaining tank weld
standards and sanitary requirements. Additional weld passes are a significant contributor
to spud distortion due to additional heat input and added filler material in beveled area of
hole. When fill passes are required, a 1/16-in. (1.58 mm) diameter weld rod is
recommended.
Note
For high pressure clamps up to 1,000 psi (69 bar), contact the factory.
Installation
Reference Manual
May 2020
00809-0100-4002
54