52
Micro Motion
®
Model 3711 Gas Flow Computers
Configuring Volumetric Flow Measurement
Figure 6-2
Mass Compensation panel
Table 6-2
Mass Compensation parameters
Parameter
Description
Comments
Enable Mass
Flow Rate
Compensation for
Pressure
• Enabled: The configured pressure correction factors are
applied to the mass flow measurement from the sensor.
• Disabled: Pressure correction factors are not applied.
Calibration
Pressure
The pressure at which the meter was calibrated (which therefore
defines the pressure at which there will be no effect on the
calibration factor).
Enter the calibration pressure from your sensor calibration
document. If no calibration pressure is provided, enter 30 PSIG.
Pressure Effect in
% of Rate per
PSIG
Enter the pressure effect for flow. Obtain the pressure effect
values from the product data sheet for your sensor, then reverse
the signs (e.g., if the pressure effect for flow is 0.000004, enter a
pressure correction factor of –0.000004).
Sometimes called the flow factor.
The highest valid value is –0.01. If
a higher value is entered, it will be
automatically changed to –0.01.
Содержание Micro Motion 3711
Страница 32: ...24 Micro Motion Model 3711 Gas Flow Computers ...
Страница 44: ...36 Micro Motion Model 3711 Gas Flow Computers ...
Страница 56: ...48 Micro Motion Model 3711 Gas Flow Computers ...
Страница 68: ...60 Micro Motion Model 3711 Gas Flow Computers ...
Страница 92: ...84 Micro Motion Model 3711 Gas Flow Computers ...
Страница 108: ...100 Micro Motion Model 3711 Gas Flow Computers ...
Страница 140: ...132 Micro Motion Model 3711 Gas Flow Computers ...
Страница 196: ...188 Micro Motion Model 3711 Gas Flow Computers ...
Страница 210: ...202 Micro Motion Model 3711 Gas Flow Computers ...
Страница 233: ......