Configuration and Use Manual
161
Administration
Adm
inis
tration
Com
p
one
n
ts
Mai
n
tenan
c
e and
T
roub
le
sh
oo
tin
g
Op
erator Int
e
rface
Figure 14-2
Model 3711 memory
14.4
Meter default values
Thirteen specific parameters in meter configuration are reset to default values after the following
occurrences:
•
After the Core Interface user program has been downloaded
•
After a security breach has been detected
•
After a cold start
•
After the units configuration (U.S. vs. metric) has been changed
Table 14-2 lists the parameters that are reset, and the default values to which they are reset.
Table 14-2
Meter default values
Meter configuration parameter
Default value
Start Totalizers
Yes
Enable Volume Calculations
No
Enable Copper RTD
No
Enable Cryogenic Modulus Compensation
No
Use Externally Written Temperature
No
Flow Direction
Forward only
Mass Flow Rate Units
lb/hr or kg/hr, according to configured units
Reserved RAM area
User configuration data
• System variables
• I/O assignment
• IO configuration
• Communications
• PID
• Database configurations
• AI calibration
Reserved RAM area
Displays
Reserved RAM area
Event and alarm logs
Reserved RAM area
Database data
Reserved RAM area
User programs
Reserved RAM area
FSTs
Copy of user configuration data
• System variables
• I/O assignment
• IO configuration
• Communications
• PID
• Database configurations
• AI calibration
Factory programs
Operating system
Functions (FST)
Default configuration
User programs
Model 3711 Core interface
Model 3711 Volume calc
Modbus
HART
...
FLASH
SRAM
Содержание Micro Motion 3711
Страница 32: ...24 Micro Motion Model 3711 Gas Flow Computers ...
Страница 44: ...36 Micro Motion Model 3711 Gas Flow Computers ...
Страница 56: ...48 Micro Motion Model 3711 Gas Flow Computers ...
Страница 68: ...60 Micro Motion Model 3711 Gas Flow Computers ...
Страница 92: ...84 Micro Motion Model 3711 Gas Flow Computers ...
Страница 108: ...100 Micro Motion Model 3711 Gas Flow Computers ...
Страница 140: ...132 Micro Motion Model 3711 Gas Flow Computers ...
Страница 196: ...188 Micro Motion Model 3711 Gas Flow Computers ...
Страница 210: ...202 Micro Motion Model 3711 Gas Flow Computers ...
Страница 233: ......