FloBoss 107 Instruction Manual
Revised June-2017
General Information
1-21
Remote configuration is possible from a host computer using a serial
communications line. You can duplicate configurations and save them to
a disk. In addition to creating a backup, this feature is useful when you
are similarly configuring multiple FB107s for the first time, or when you
need to make configuration changes off-line. Once you create a backup
configuration file, you can load it into an FB107 with the Download
function (
File
>
Download
).
Access to the FB107 is restricted to authorized users with correct user ID
and password.
You can build custom displays for the FB107 in ROCLINK 800 that
combine both graphic and dynamic data elements. The displays can
monitor the operation of the FB107 either locally or remotely.
You can archive historical values for any numeric parameter in the
FB107. For each parameter configured for historical archiving, the system
keeps time-stamped minute, periodic, and daily data values as well as
yesterday’s and today’s daily minimum and maximum values.
You can collect history values from the FB107 using ROCLINK 800 or
another third-party host system. You can view history directly from the
FB107 or from a previously saved disk file. For each history segment,
you can configure the number of periodic history values archived, the
frequency of archiving the periodic values, the number of daily values
archived, and the contract hour.
ROCLINK 800 can create an EFM (Electronic Flow Measurement) report
file that contains all configuration, alarms, events, periodic and daily
history logs, and other history logs associated with the meter runs in the
FB107. This file then becomes the custody transfer audit trail.
Use ROCLINK 800 to:
Configure and view input/output (I/O) points, flow calculations, meter
runs, PID control loops, system parameters, and power management
features.
Retrieve, save, and report historical data.
Retrieve, save, and report events and alarms.
Perform two-, three-, four-, or five-point calibration on analog inputs
and Multi-Variable Sensor (MVS) inputs.
Perform two-, three-, four-, or five-point calibration on RTD inputs.
Implement user security.
Create, save, and edit graphical displays.
Create, save, edit, and debug Function Sequence Tables (FSTs) of up
to 3000 bytes.
Set up communication parameters.
Configure Modbus parameters.
Update the firmware.