DVC6200f Digital Valve Controller
November 2010
140
Table 4-40. Input Selector Function Block Parameter Definitions (Continued)
Label
PARAMETER_NAME
Description
Initial
Value
Range
Block
Mode
RO /
RW
Index
Number
Update Event
UPDATE_EVT
23
Data Type: DS-73
This alert is generated by any change to the static
data.
UNACKNOWLEDGED
23.1
RW
N/A
0=Undefined
1=Acknowledged
2=Unacknowledged
0
UPDATE_STATE
23.2
RO
N/A
0=Undefined
1=Update Reported
2=Updated not
reported
0
TIME_STAMP
23.3
RO
N/A
0
STATIC_REVISION
23.4
RO
N/A
0
RELATIVE_INDEX
23.5
RO
N/A
0
Block Alarm
BLOCK_ALM
24
Data Type: DS-72
The block alarm is used for all configuration,
hardware, connection failure, or system problems in
the block. The cause of the alert is entered in the
subcode field. The first alert to become active will set
the active status in BLOCK_ERR. As soon as the
Unreported status is cleared by the alert reporting
task, another block alert may be reported without
clearing the Active status, if the subcode has
changed.
UNACKNOWLEDGED
24.1
RW
N/A
0=Undefined
1=Acknowledged
2=
Unacknowledged
0
ALARM_STATE
24.2
RO
N/A
0=Undefined
1=Clear reported
2=Clear not reported
3=Active reported
4=Active not
reported
0
TIME_STAMP
24.3
RO
N/A
0
SUBCODE
24.4
RO
N/A
0
VALUE
24.5
RO
N/A
0
Extended Parameters
In 5
IN_5
25
ALL
Status
BAD
NC
constant
Data Type: DS-65
Input value and status.
Value
0
In 6
IN_6
26
ALL
Status
BAD
NC
constant
Data Type: DS-65
Input value and status.
Value
0
In 7
IN_7
27
ALL
Status
BAD
NC
constant
Data Type: DS-65
Input value and status.
Value
In 8
IN_8
28
ALL
Status
BAD
NC
constant
Data Type: DS-65
Input value and status.
Value
0
Disable Analog Input 5
DISABLE_5
29
ALL
Status
BAD
NC
constant
Data Type: DS-66
Enable/Disable for Input_5, If parameter is TRUE
then input is disabled. If parameter status is BAD it is
not evaluated.
Value
0=Use
1=Disable
0
Disable Analog Input 6
DISABLE_6
30
ALL
Status
BAD
NC
constant
0
Data Type: DS-66
Enable/Disable for Input_6, If parameter is TRUE
then input is disabled. If parameter status is BAD it is
not evaluated.
Value
0=Use
1=Disable
0
Disable Analog Input 7
DISABLE_7
31
ALL
Value
BAD
NC
constant
Data Type: DS-66
Enable/Disable for Input_7, If parameter is TRUE
then input is disabled. If parameter status is BAD it is
not evaluated.
Status
0=Use
1=Disable
0
−
Continued
−
4
Содержание FIELDVUE DVC6200f
Страница 42: ...DVC6200f Digital Valve Controller November 2010 30 4 ...
Страница 60: ...DVC6200f Digital Valve Controller November 2010 48 4 ...
Страница 108: ...DVC6200f Digital Valve Controller November 2010 96 4 ...
Страница 122: ...DVC6200f Digital Valve Controller November 2010 110 4 ...
Страница 188: ...DVC6200f Digital Valve Controller November 2010 176 4 ...
Страница 200: ...DVC6200f Digital Valve Controller November 2010 188 4 ...
Страница 216: ...DVC6200f Digital Valve Controller November 2010 204 5 ...
Страница 250: ...DVC6200f Digital Valve Controller November 2010 238 8 ...
Страница 251: ...Principle of Operation November 2010 239 A A Appendix A Principle of Operation Digital Valve Controller Operation 240 A ...
Страница 254: ...DVC6200f Digital Valve Controller November 2010 242 A ...
Страница 284: ...DVC6200f Digital Valve Controller November 2010 272 D ...
Страница 290: ...DVC6200f Digital Valve Controller November 2010 278 E ...
Страница 308: ...DVC6200f Digital Valve Controller November 2010 296 F ...
Страница 312: ...DVC6200f Digital Valve Controller September 2010 300 Notes G Glossary ...
Страница 324: ...DVC6200f Digital Valve Controller November 2010 312 F Index ...
Страница 325: ...This page intentionally left blank ...