When configured as digital outputs, the channels have the following characteristics:
Table 3-5: Digital Output Characteristics
Type
Number Supported
Characteristics
Digital Output (DO)
2 dedicated channels
Contact closure by solid state relay
Maximum current of 500mA at
31VDC
Can be configured to fail at last
output value or fail to a fault state.
You can enable an internal ground
switch in FBxConnect, connecting
the low side to ground.