132 Appendix 1 Parameter Set
EV1000 Series General Purpose Variable Speed Drive User Manual
Group FL: Protection Parameters
Para.
Name
Range
Unit
Default Modification
FL.14
Fault type of
the first time
FL.15
Fault type of
the second
time
FL.16
Fault type of
the third time
(latest)
0: not fault
1: overcurrent during acceleration (E001)
2: overcurrent during deceleration (E002)
3: overcurrent during constant-speed running (E003)
4: overvoltage during acceleration (E004)
5: overvoltage during deceleration (E005)
6: overvoltage during constant-speed running ( E006)
7: drive’s control power supply overvoltage (E007)
8: Reserved
9: output phase loss (E009)
10: Reserved
11: heatsink overheat (E011)
12: Reserved
13: drive overload (E013)
14: motor overload (E014)
15: emergency stop or external device fault (E015)
16: E
2
PROM fault (E016)
17: RS485 communication fault (E017)
18: Reserved
19: current-detection circuit fault (E019)
20: System disterbed ( E020)
21: Reserved
22: Reserved
23: Reserved
24: Auto tuning fault ( E024)
1 0
*