Group 7: Multi-function Terminals
Para.
Name
Range
Unit
Default Modification
F7.30
AO1 output gain
0.0
~
200.0
%
0.1
%
100.0
%
○
F7.31
AO2 output gain
0.0
~
200.0
%
0.1
%
100.0
%
○
F7.32
Y2 max. pulse freq.
0.1
~
50.0 kHz
0.1 10.0k
○
F7.33
Preset counting value
F7.34
~
9999
1 0
○
F7.34
Specified counting value
0
~
F7.33
1 0
○
F7.35
Positive or negative logic of
terminal
Positive logic: Xi connects with common
terminal is valid, otherwise invalid.
Negative logic: Xi connects with common
terminal is invalid, otherwise valid.
One’s place of F7.35:
BIT0
~
BIT3: X1
~
X4
One’s place of F7.35:
BIT0: X5
BIT1
~
BIT3: Reserved
Hundred’s place of F7.35:
BIT0
~
BIT1: FWD
、
REV
BIT2
~
BIT3: Y1
、
Y2
1 000
○