DL8000 Preset Instruction Manual
Revised February-2016
Communications Protocols
D-65
Some of the transaction data is archived by default
and not configurable. Refer to
Section C.2.5,
Transaction History
in
Appendix C
of the
ROCLINK 800 Configuration Software User
Manual (for DL8000)
, (Form A6240) for details.
The parameter values are returned in the same
order in which the configuration bits are reported.
All the copies archived for each configured archive
parameter are returned in the response frame.
The number of copies archived for each parameter
is always fixed. For example,
4
for data referring to
components,
4
for data referring to meters, and
6
for data referring to additives.
Example: If configstatus[6](hex) = 0D 90 00 00 00
00, then data following the configstatus[6] in the
response frame is formatted as:
float Unit Address
float Data Item 1
float Data Item 2
float Trans Start Gross Meter 1
float Trans Start Gross Meter 2
float Trans Start Gross Meter 3
float Trans Start Gross Meter 4
float Trans End Gross Meter 1
float Trans End Gross Meter 2
float Trans End Gross Meter 3
float Trans End Gross Meter 4
Note
: The DL8000 does not consider the
multiplication factors used for returning
some parameters in other DanLoad 6000
commands when returning the value (read
from the archived data) in the response
frame.
Request Stored
Batch
[0x3A]
Use this command to request the batch record from the (transaction storage)
batch file. You can configure the format of the batch record; the DL8000
archives only the configured parameters. Valid batch sequence numbers are
0 through 9999.
Flags Immediately Set
None
Flags Immediately
Cleared
None
Exceptions
1Eh Batch not on file
03h Response Data Field Too Long
Supporting
Parameters
None
Results
The DL8000 customizes the response frame when
returning the batch record, as described in the
Deviation section.
Deviations
The command query frame has the following
format:
struct Tasq
{
Unsigned char dfl; // datafield length
Unsigned char cmdcode; // command code
baseq; // batch sequence number
};