DL8000 Preset Instruction Manual
D-40
Communications Protocols
Revised February-2016
Set Densities/Gravity
[0x0B]
Sets the density/gravity for all the products/components in the batch prior to
authorizing a batch. If the use_gord flag received for each component in the
command request frame is set to 1, then value of density/gravity is set to
product base density [72,x,8]. The units of gravity or density should be same
as those configured in the DL8000 at parameter Density Units Option [70,0,3].
If there is an online input to the TAS, update the backup densities or gravities
using the Authorize Batch [0x0A] command. If these values are provided
manually, use the Set Densities/Gravity command to send the updated
density or gravity values to the DL8000.
Flags Immediately Set
None
Flags Immediately
Cleared
None
Exceptions
Primary Alarm
Batch Authorized
Operating Mode is Manual
Invalid program code value
Invalid number of component
Supporting
Parameters
Product base density [72,x,8]
Results
None
Deviations
Does not support exceptions “Program Code
Value is Weights & Measures” and “Program
Code is Read-only.”
If TAS tries to set the backup density using
this command, the DL8000 updates the base
density of the corresponding product.
End Batch
[0x0D]
Ends an in-progress batch which has halted or aborts an authorized batch
which has not started.
Under normal circumstances a batch ends itself when the preset volume of all
the components in the blend or recipe has been delivered.
The End Batch command is
not
the same as the Stop Batch command
[0x0F]. The Stop Batch command simulates the Stop key being pressed,
which potentially allows the batch to be restarted.
You can also end a batch by pressing
Stop
when the batch is halted without
any active alarm having severity more than info.
Flags Immediately Set
Batch Ended (if batch was in progress)
or
Batch Aborted (if batch was not in progress)
Flags Immediately
Cleared
Batch in Progress
Batch Stopped
Batch Authorized
K&D Locked Out
Содержание DL8000
Страница 82: ...DL8000 Preset Instruction Manual 3 44 Modules Revised February 2016 This page is intentionally left blank ...
Страница 118: ...DL8000 Preset Instruction Manual B 26 Modbus Communications Revised February 2016 This page is intentionally left blank ...
Страница 329: ...DL8000 Preset Instruction Manual Revised February 2016 I 7 This page is intentionally left blank ...