DL8000 Preset Instruction Manual
Revised February-2016
Communications Protocols
D-43
Batch Data
by Component
[0x10]
Once a batch ends, the DL8000 sets a flag to indicate that the batch has
ended and cannot be restarted. The TAS system can then use this command
to request the data for the batch.
Flags Immediately Set
None
Flags Immediately
Cleared
None
Exceptions
Operating Mode is Manual
No batch is ended
Supporting
Parameters
Preset delivery type [63,0,29]
Results
The response frame includes the following
parameter values:
Batch sequence number [63,0,125]
Transaction sequence number [63,0,124]
Recipe number [63,0,118]
Current swing arm side [63,0,145] (applicable
only for Version 2.0 and later)
Batch start date and time [63,0,232]
Batch end date and time [63,0,233]
Number of meters [63,0,20]
Number of components [63,0,21]
Number of additives [63,0,100]
Number of data prompts [63,0,186]
Meter Gross Batch start total snapshot
[75,x,40]
Meter Net std or Mass Batch start total
snapshot [75,x,41 or 42] based on delivery
type
Meter Gross Batch end total snapshot
[75,x,43]
Meter Net std or Mass Batch end total
snapshot [75,x,44 or 45] based on delivery
type
Component Gross Batch Totals [69,x,25]
Component Net std or Mass Batch Totals
[69,x,27 or 28]
Component Avg (FWA) Batch Temperature
[69,x,61]
Component Avg (FWA) Batch Density
[69,x,100]
Component Avg (FWA) Batch Pressure
[69,x,72]
Actual component % in batch [69,x,59]
Additive Batch totals [67,x,13]
Data items entered
[63,0,188;190;192;194;196]