DL8000 Preset Instruction Manual
D-14
Communications Protocols
Revised February-2016
In the DanLoad 6000 protocol, the TAS uses the Transaction Data by
Component command (hex 0x1F) to obtain transaction data (transaction
volumes, meter totals, data items, etc.) from the DL8000.
D.2.5 Batching Status States
The Batching Status parameter [63,0,9] maintains various process
values which the TAS uses to monitor the status of both the DL8000
and the overall batching operation.
Note
:
These values accumulate in the TLP and do not currently appear
on any system report or screen.
State
Description
Notes
0
Idle
1
Select_Recipe
2
Invalid_Recipe
3
Enter_Preset
4
Invalid_Preset
5
Batch_Auth
10
Alarm_Batch_Halt
12
User_Batch_Halt
13
Batch_Complete
20
Start_Pump
Ratio blending only
21
Line_Pack
22
Wait_for_Line_Pack
23
Flow_Control
24
Valve_Close
25
Pump_Stop_Delay
26
Wait_for_Pump_Stop
27
Stop_Pump
28
Wait_All_Stop
29
Batch_Halt
30
Next_Component
Sequential blending only
31
Line_Flush
32
End_of_Batch
33
Wait_Full_Valve_Close
34
Close_Block_Valve
37
End_Batch
38
End_Transaction
50
Select_Additive
60
Archive_Transaction