DL8000 Preset Instruction Manual
D-52
Communications Protocols
Revised February-2016
Display Message
[0x1C]
Deviations
The DanLoad 6000 has capacity to display a
128-character long text message. The DL8000
supports the first 20 characters of text
message received.
In the DanLoad 6000, if prompt field width is
greater than 0, the timeout timer is started
again whenever a key is pressed. If prompt
field width is zero, a timeout occurs after the
specified timeout time. In the DL8000, the
prompt field width does not affect the timeout
time.
Request
Keypad Data
[0x1D]
Retrieves input requested via Display Message command [0x1C]. When
keypad input is terminated, the DL8000 sets a flag to indicate that the keypad
data is available.
Flags Immediately Set
None
Flags Immediately
Cleared
None
Exceptions
Batch in progress
Primary alarm active
No keypad data available
Operating mode is manual
Supporting
Parameters
None
Results
Value stored at [63,0,177] is returned in response.
Deviations
None
Содержание DL8000
Страница 82: ...DL8000 Preset Instruction Manual 3 44 Modules Revised February 2016 This page is intentionally left blank ...
Страница 118: ...DL8000 Preset Instruction Manual B 26 Modbus Communications Revised February 2016 This page is intentionally left blank ...
Страница 329: ...DL8000 Preset Instruction Manual Revised February 2016 I 7 This page is intentionally left blank ...