4.3
Configuration of the turbine meter
The Daniel factory configures the turbine meter internal components. Inspect the internal
components before installation.
4.3.1
Orientation and position of the turbine meter
Flow direction
Turbine meters can be used for uni-directional or bi-directional flows. The design of the
internal features of the meter housing and the internal components depend on the
desired configuration. Install the LTM carefully so it complies with the correct inlet and
outlet sides (See label on the turbine meter for inlet direction).
Flow conditioning
The flow stream must be free of swirl for a turbine meter to perform consistently and
accurately. The internal assembly supports of a turbine meter offer a slight straightening
effect. If additional flow conditioning is required, use straightening vanes or tube bundles.
Refer to API MPMS, Chapter 5, Section 3.
A flow conditioning plate is available for all standard series 1500 LTM, NPS 3 through 8. It is
designed to eliminate product flow characteristics such as liquid swirl and non-uniform
velocity profiles (induced by piping configurations and other elements of the system) that
may impede accurate measurement within the turbine meter run.
The plate is installed directly into the inlet of the turbine meter. Due to the flow
conditioning influence on the incoming product, the need for upstream flow straightening
piping is reduced. It is recommended that a minimum of five pipe diameters be
maintained upstream and downstream of the turbine meter to ensure accurate operation.
Actual length is determined by piping requirements specific to the application.
User manual
Prepare the turbine meter for use
P/N 3-9008-515
March 2019
User manual
61
Содержание Daniel Series
Страница 1: ...User manual P N 3 9008 515 Rev AF March 2019 Daniel Series 1500 Liquid Turbine Meter NPS 3 through 24 ...
Страница 2: ...2 ...
Страница 11: ...Part I Plan User manual Plan P N 3 9008 515 March 2019 User manual 11 ...
Страница 12: ...Plan User manual March 2019 P N 3 9008 515 12 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 69: ...Part II Install User manual Install P N 3 9008 515 March 2019 User manual 69 ...
Страница 70: ...Install User manual March 2019 P N 3 9008 515 70 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 78: ...Testing User manual March 2019 P N 3 9008 515 78 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 79: ...Part III Operate User manual Operate P N 3 9008 515 March 2019 User manual 79 ...
Страница 80: ...Operate User manual March 2019 P N 3 9008 515 80 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 83: ...Part IV Maintain User manual Maintain P N 3 9008 515 March 2019 User manual 83 ...
Страница 84: ...Maintain User manual March 2019 P N 3 9008 515 84 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 105: ...User manual P N 3 9008 515 March 2019 User manual 105 ...