Figure 2-1: Effects of back pressure
Back pressure calculation
Equation 2-2: Back pressure calculation
P
b
≥ 2Δp + 1.25p
e
P
b
Minimum back pressure, pounds per square inch gauge (psig)
Δp
Pressure drop through the meter at the maximum operating flow rate for the liquid
being measured, pounds per square inch (psi).
P
e
Equilibrium vapor pressure of the liquid at the operating temperature, pounds per
square inch absolute (psia), gauge pressure plus atmospheric pressure.
Additional devices for accurate measurement
Valves
The metering system should have a flow rate control valve located at a convenient
distance downstream of all measurement equipment. The function of the control valve is
to limit and maintain system pressure on the meter. This avoids cavitation.
Valves should be capable of rapid, smooth opening and closing with positive shut-off.
•
When used for intermittent flow, valves should be fast-acting and shock-free.
•
Bypass lines should be equipped with blind or positive shutoff devices.
•
Shut-off or control valves should be located downstream of the turbine meter.
User manual
Operating conditions and specifications
P/N 3-9008-515
March 2019
User manual
45
Содержание Daniel Series
Страница 1: ...User manual P N 3 9008 515 Rev AF March 2019 Daniel Series 1500 Liquid Turbine Meter NPS 3 through 24 ...
Страница 2: ...2 ...
Страница 11: ...Part I Plan User manual Plan P N 3 9008 515 March 2019 User manual 11 ...
Страница 12: ...Plan User manual March 2019 P N 3 9008 515 12 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 69: ...Part II Install User manual Install P N 3 9008 515 March 2019 User manual 69 ...
Страница 70: ...Install User manual March 2019 P N 3 9008 515 70 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 78: ...Testing User manual March 2019 P N 3 9008 515 78 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 79: ...Part III Operate User manual Operate P N 3 9008 515 March 2019 User manual 79 ...
Страница 80: ...Operate User manual March 2019 P N 3 9008 515 80 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 83: ...Part IV Maintain User manual Maintain P N 3 9008 515 March 2019 User manual 83 ...
Страница 84: ...Maintain User manual March 2019 P N 3 9008 515 84 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 105: ...User manual P N 3 9008 515 March 2019 User manual 105 ...