Important
Ensure that once the nut is tightened, two threads outside the nut are exposed. The only
exception is when a flange requires hydraulic bolt tensioning. The manufacturer of the
hydraulic bolt tensioning equipment will specify number of exposed threads outside the
nut.
•
Do not use damaged or worn stud bolts or nuts.
•
Do not use nuts or stud bolts that do not fit correctly together.
•
Do not use nuts or stud bolts without grade or type identification.
•
Do not mix nuts or stud bolts of different coatings. Different nut and stud bolt coatings
require different torques to achieve the same bolt tension.
•
Do not assemble nuts with the identification hard stamp against the back face of the
flange
Flange stud bolt and nut storage
Remove each nut and bolt as a pair. Thread the matching nut back onto the bolt. Stack
them in a fashion that will not cause thread damage.
Reuse of flange stud bolts and nuts
Daniel Quality Control permits the reuse of threaded fasteners under the following
conditions:
•
Fasteners are clean, free of corrosion, paint, thread damage, cracks, teeth marks
(caused by wrenches) or other signs of damage.
•
Fasteners are not tightened to or beyond their yield strength.
•
Fasteners have not lost their coating.
Compare the threads of a used stud bolt with the thread of a new stud bolt. Finger-tighten
the nut over the entire length of the bolt.
6.3
Assemble the electronic components
Follow the procedure below to install the LME and/or the RME electronics.
Prerequisites
WARNING
VOLTAGE HAZARD
Disconnect equipment from power before opening the LME and/or RME. Do not open
them while power is on and an explosive gas atmosphere is present.
Failure to comply may result in death or serious injury.
Procedure
1. Remove the security seal wire.
2. Remove the security latch using the 3 mm Allen key.
Installation procedure
User manual
March 2019
P/N 3-9008-515
74
Daniel Series 1500 Liquid Turbine Meter, NPS 3-24
Содержание Daniel Series
Страница 1: ...User manual P N 3 9008 515 Rev AF March 2019 Daniel Series 1500 Liquid Turbine Meter NPS 3 through 24 ...
Страница 2: ...2 ...
Страница 11: ...Part I Plan User manual Plan P N 3 9008 515 March 2019 User manual 11 ...
Страница 12: ...Plan User manual March 2019 P N 3 9008 515 12 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 69: ...Part II Install User manual Install P N 3 9008 515 March 2019 User manual 69 ...
Страница 70: ...Install User manual March 2019 P N 3 9008 515 70 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 78: ...Testing User manual March 2019 P N 3 9008 515 78 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 79: ...Part III Operate User manual Operate P N 3 9008 515 March 2019 User manual 79 ...
Страница 80: ...Operate User manual March 2019 P N 3 9008 515 80 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 83: ...Part IV Maintain User manual Maintain P N 3 9008 515 March 2019 User manual 83 ...
Страница 84: ...Maintain User manual March 2019 P N 3 9008 515 84 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 105: ...User manual P N 3 9008 515 March 2019 User manual 105 ...