1
Introduction
1.1
Purpose of this manual
Daniel Measurement and Control Inc. designed this manual to guide owners and
personnel in the installation, operation and maintenance of the Daniel
TM
Series 1500
Liquid Turbine Meter Manual, 3-9008-515. It is imperative that product owners and
operation personnel read and follow the information contained in this manual to ensure
that the turbine meter is installed correctly and is operating according to the design,
certifications and safety considerations.
1.2
Description of the Series 1500 Liquid Turbine
Meter (LTM)
1.2.1
General features of the turbine meter
The Daniel Series 1500 Liquid Turbine Meter (LTM) is a volumetric flow metering and
transmitting device used for accurate measurement of crude oil hydrocarbons and other
related process fluids. The design allows high operational flow rates, extended flow ranges
and sustained performance capability. This meter is specifically designed for pipeline
service where a vital characteristic is repeatability.
The turbine meter is designed for use within the guidelines of
API Manual of Petroleum
Measurement Standards (MPMS)
, Chapter 5.3 and test procedures of API MPMS, Chapter 4
(Prover systems).
The meter consists of two main parts: Local Mounted Enclosure (LME) assembly and the
meter body housing assembly. For certain functions, the meter will have a Remote
Mounted Enclosure (RME), another version of the LME.
The LME is an explosion-proof, weather-resistant housing for dual pickoffs, as well as an
encapsulated preamplifier. It also serves as the mechanical mounting connection
necessary for local and remote accessories.
Note
Daniel offers electronic enclosures with different housing materials and electronic
configurations.
Local Mounted Enclosure (LME)
The LME consists of an electrical enclosure and a solid cover made of stainless steel. This
configuration contains a mounting bracket and a preamplifier which works with two
standard pickoff coils mounted into the meter housing.
The electrical enclosure contains an external and an internal grounding lug. The two
enclosure openings are plugged with stainless steel plugs. Refer to
User manual
Introduction
P/N 3-9008-515
March 2019
User manual
13
Содержание Daniel Series
Страница 1: ...User manual P N 3 9008 515 Rev AF March 2019 Daniel Series 1500 Liquid Turbine Meter NPS 3 through 24 ...
Страница 2: ...2 ...
Страница 11: ...Part I Plan User manual Plan P N 3 9008 515 March 2019 User manual 11 ...
Страница 12: ...Plan User manual March 2019 P N 3 9008 515 12 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 69: ...Part II Install User manual Install P N 3 9008 515 March 2019 User manual 69 ...
Страница 70: ...Install User manual March 2019 P N 3 9008 515 70 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 78: ...Testing User manual March 2019 P N 3 9008 515 78 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 79: ...Part III Operate User manual Operate P N 3 9008 515 March 2019 User manual 79 ...
Страница 80: ...Operate User manual March 2019 P N 3 9008 515 80 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 83: ...Part IV Maintain User manual Maintain P N 3 9008 515 March 2019 User manual 83 ...
Страница 84: ...Maintain User manual March 2019 P N 3 9008 515 84 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 105: ...User manual P N 3 9008 515 March 2019 User manual 105 ...