Table 1-2: Meter specifications
(continued)
Liquid Meter specifications
Body and Flange Pressure rating range
U.S. Customary Units - Meter sizes 4 inches to 24
inches (Raised face, RTJ or Companion)
•
Line sizes:
—
4” inches (DN 100)
—
6” inches (DN 150)
—
8” inches (DN 200)
—
10” inches (DN 250)
—
12” inches (DN 300)
—
16” inches (DN 400)
—
18” inches (DN 450)
—
20” inches (DN 500)
—
24” inches (DN 600)
•
ANSI pressure classes (per ANSI B16.5):
—
150 ANSI / PN 20
—
300 ANSI / PN 50
—
600 ANSI / PN 100
—
900 ANSI / PN 150
—
1500 ANSI/PN 200
•
Body and flange material and temperature
ratings:
—
Carbon Steel body and Flanges: (-45 °C
to 150 °C)
—
316 Stainless steel body and flanges:
(-50 °C to 150 °C)
—
316L Stainless steel body and flanges:
(-50 °C to 150 °C)
—
Carbon Steel body and flanges: (-50 °C to
150 °C)
•
Maximum Pressures
—
Dependent on operating temperature
•
Minimum Pressures
—
0 psig 0 barg
Meter bore
•
Schedule 20, 30, 40, 80, 120, 160, LW, XS,
XXS and Standard
Flange types
•
Raised face or RTJ
Specific Gravity
•
0.35 to 1.50
Introduction
Installation manual
May 2019
3-9000-760
20
3814 Liquid Ultrasonic Flow Meter
Содержание Daniel 3814
Страница 1: ...Installation manual 3 9000 760 Rev HA May 2019 Daniel 3814 Liquid Ultrasonic Flow Meter ...
Страница 2: ...2 ...
Страница 10: ...Contents Installation manual May 2019 3 9000 760 x 3814 Liquid Ultrasonic Flow Meter ...
Страница 48: ...Mechanical Installation Installation manual May 2019 3 9000 760 48 3814 Liquid Ultrasonic Flow Meter ...
Страница 92: ...Configuration Installation manual May 2019 3 9000 760 92 3814 Liquid Ultrasonic Flow Meter ...
Страница 94: ......
Страница 95: ......
Страница 96: ......
Страница 97: ......
Страница 98: ...Engineering Drawings Installation manual May 2019 3 9000 760 94 3814 Liquid Ultrasonic Flow Meter ...