Computer simulations of various velocity profiles demonstrate that multiple
measurement paths provide an optimum solution for measuring asymmetric flow. The
Daniel 3814 Liquid Ultrasonic Flow Meter utilizes four cross-bore, parallel-plane
measurement paths, offers a high degree of repeatability, bi-directional measurement and
superior flow capabilities for custody transfer without the compromises associated with
conventional technologies.
The Daniel 3814 Liquid Ultrasonic Flow Meter’s U.L. safety listing is accomplished through
the combination of an explosion-proof Transmitter Electronics Enclosure that houses the
CPU Module, Power Supply board, I.S. Barrier board, Backplane board and optional LCD
Display board.
Important
The optional LCD Display requires firmware v1.04 or later and Uboot version, January 31,
2013.
The Base Electronics Enclosure is intrinsically safe and houses the Acquisition Module, the
acquisition cable and wiring. The Intrinsically safe transducers and cable assemblies are
designed for Class 1, Division 1, Groups C and D areas without need of further protection
when installed in accordance with the field wiring diagram (refer to Daniel drawing
DMC-004936, the Daniel 3814 Liquid Ultrasonic Flow Meter’s U.L. safety listing is
accomplished through the combination of an explosion-proof Transmitter Electronics
Enclosure that houses the CPU Module, the Base Electronics Enclosure that houses the
Acquisition Module with intrinsically safe transducers and cable assemblies designed for
Class 1, Division 1, Groups C and D areas without need of further protection when installed
in accordance with the field wiring diagram (refer to Daniel drawing DMC-004936, see
) and
1.7
Meter specifications
CAUTION
FLUID CONTENTS MAY BE HAZARDOUS
The meter must be fully depressurized and drained before attempting to remove the
transducer housing. If fluid begins to leak from the transducer housing, immediately
reinstall it.
Failure to comply may cause serious injury or equipment damage.
CAUTION
ESCAPING FLUIDS HAZARD
The purchaser of the meter is responsible for the selection of Daniel components/seals
and materials compatible with the chemical properties of the measurement fluid.
Failure to select suitable meter components/seals may cause escaping fluids, resulting
in injury or equipment damage.
Consult your Daniel Sales and Service representative to ensure you purchase the correct
components and seals for your application.
Specifications for Daniel 3814 Liquid Ultrasonic Flow Meters are below:
Introduction
Installation manual
May 2019
3-9000-760
18
3814 Liquid Ultrasonic Flow Meter
Содержание Daniel 3814
Страница 1: ...Installation manual 3 9000 760 Rev HA May 2019 Daniel 3814 Liquid Ultrasonic Flow Meter ...
Страница 2: ...2 ...
Страница 10: ...Contents Installation manual May 2019 3 9000 760 x 3814 Liquid Ultrasonic Flow Meter ...
Страница 48: ...Mechanical Installation Installation manual May 2019 3 9000 760 48 3814 Liquid Ultrasonic Flow Meter ...
Страница 92: ...Configuration Installation manual May 2019 3 9000 760 92 3814 Liquid Ultrasonic Flow Meter ...
Страница 94: ......
Страница 95: ......
Страница 96: ......
Страница 97: ......
Страница 98: ...Engineering Drawings Installation manual May 2019 3 9000 760 94 3814 Liquid Ultrasonic Flow Meter ...