Procedure
1. Install security wire seal into and through two of the four the holes in the socket
head screws on the Base Enclosure cover (maximum wire diameter .078 inch;
2.0mm).
Figure 3-11: Base Enclosure security seals
A. Base Enclosure
B. Security wire seals
2. Position the wire to prevent counterclockwise rotation of the screws when the seal
wire is taut.
3. Feed the security wire beneath the Transmitter Electronics Enclosure and through
the adjacent socket head screw. Twist the wire, removing all slack and seal.
Electrical Installation
Installation manual
May 2019
3-9000-760
66