c) Click the
Set Flow Range Limits
button and enter a positive value for the
Flow Analysis Lower Velocity Range and the Upper Velocity Range Limits.
When the velocity is outside of the limit parameters, an alert is triggered.
Click the
Next
button to display the Method Complete page.
14. Click the
Service Tools
tab to access the device alerts, variables, trends and
maintenance statuses or to edit the configuration parameters.
a) Click the
Service Tools
→
Alerts
tab. If an alert condition exists, the alert type
and description displays. Recommended actions are listed to assist you in a
resolution. After you resolve the alert condition, click the
Acknowledge
button to clear the alert. Click
Apply
to write the changes to the meter. If no
alert condition is active, click
OK
to close the device window.
Figure 4-15: AMS Device Manager - Service Tools Alerts
b) If you change the device configuration, a confirmation dialog displays and
prompts you to write the changes to the meter. Click
Yes
to write the
changes to the meter or click
No
to cancel pending changes.
Installation manual
Configuration
3-9000-760
May 2019
Installation manual
85
Содержание Daniel 3814
Страница 1: ...Installation manual 3 9000 760 Rev HA May 2019 Daniel 3814 Liquid Ultrasonic Flow Meter ...
Страница 2: ...2 ...
Страница 10: ...Contents Installation manual May 2019 3 9000 760 x 3814 Liquid Ultrasonic Flow Meter ...
Страница 48: ...Mechanical Installation Installation manual May 2019 3 9000 760 48 3814 Liquid Ultrasonic Flow Meter ...
Страница 92: ...Configuration Installation manual May 2019 3 9000 760 92 3814 Liquid Ultrasonic Flow Meter ...
Страница 94: ......
Страница 95: ......
Страница 96: ......
Страница 97: ......
Страница 98: ...Engineering Drawings Installation manual May 2019 3 9000 760 94 3814 Liquid Ultrasonic Flow Meter ...