64
Outputs test mode
Section 5: Calibrate and configure the meter
3410 Series Gas Ultrasonic Meters Operations Manual
January 2018
3-9000-777 Rev E
5.7
Outputs test mode
The Daniel 3410 Gas Ultrasonic Flow Meters provides a mode of operation for testing the
frequency, current (analog) and digital output signals. Entering, configuring, and exiting this
mode is accomplished by setting data points using the Daniel MeterLink
Tools|Outputs Test
.
Figure 5-12 Meter Outputs Test Page
Note:
The AO2 is only available with CPU module, part number 1-360-03-010.
The Outputs Test dialog box allows you to monitor the live values of all the frequency, current
(analog) and digital outputs. Additionally the outputs can be set into a Test mode to force the
outputs to a specific user defined value. This dialog box is only available while connected to a
meter.
When the dialog box first opens, the available Outputs show the current “Live” values the
outputs are driving. The LED Test mode will remain gray while not in Test mode.
To fix the frequency and current outputs to a user-defined value, enter the desired percentage of
full-scale into the Output setting. For Daniel 3410 Gas Ultrasonic Flow Meters, each available
output has individual output control and can be set from 0 to 150%. The 100% Scaling indicates
the full scale value for the frequency outputs and can be changed from the Field Setup Wizard.