Configure Frequency outputs
Section 5: Calibrate and configure the meter
3410 Series Gas Ultrasonic Meters Operations Manual
January 2018
3-9000-777 Rev E
•
Energy Rate - The following fields are used to configure the frequency or current outputs
selected to output an energy rate. The fields are only enabled if the associated output’s
Content is set to Energy rate.
–
Full scale energy rate used with output: Enter the energy rate to be equivalent to the
maximum frequency of the frequency output.
–
Energy/pulse: A read-only value showing the calculated inverse of the K-factor. Each
frequency output has its own register.
•
Mass Rate
–
The following fields are used to configure the frequency outputs selected to output
a mass rate. The fields are only enabled if the associated output’s Content is set to
Mass rate.
–
Full scale mass rate used with output: Enter the mass rate to be equivalent to the
maximum frequency of the frequency output.
–
Mass/pulse: A read-only value showing the calculated inverse of the K-factor. Each
frequency output has its own register.