ii
Contents
PrefaceTable of Contents
3410 Series Gas Ultrasonic Meters Operations Manual
January 2018
3-9000-777 Rev E
4.5.1
Raw volumetric flow rate .........................................................................................29
4.5.2
Flow-condition volumetric flow rate ........................................................................29
4.5.3
Pressure-effect expansion correction.......................................................................30
4.5.4
Temperature-effect expansion correction................................................................31
4.5.5
Profile-effect correction...........................................................................................32
4.5.6
Reynolds number.....................................................................................................33
4.5.7
Base-condition volumetric flow rate ........................................................................34
4.5.8
Volume....................................................................................................................34
4.5.9
Energy rate and totals..............................................................................................35
4.5.10
Mass rate and totals ..............................................................................................36
4.6
3410 Series gas flow meter characterizations .................................................... 37
Section 5: Calibrate and configure the meter
5.1
Calibration methods ........................................................................................ 39
5.1.1
Dry calibration .........................................................................................................39
5.1.2
Wet calibration ........................................................................................................43
5.1.3
Wet calibration piece-wise linearization...................................................................44
5.1.4
Third-order polynomial............................................................................................47
5.1.5
No wet calibration ...................................................................................................49
5.1.6
Triggered Delta Volumes .........................................................................................49
5.3
Calibrate Analog inputs and outputs ................................................................. 52
5.4
Calibrate meter factors .................................................................................... 55
5.4.1
Flow calibration .......................................................................................................55
5.4.2
Configure Frequency/Digital output sources ...........................................................57
5.5
Configure Frequency outputs ........................................................................... 61
5.6
Configure digital input/outputs ........................................................................ 63
5.7
Outputs test mode .......................................................................................... 64
5.8
Configure HART outputs .................................................................................. 65
5.8.1
Configure the four dynamic variables ......................................................................65
5.8.2
Configure the device identification ..........................................................................66
5.8.3
Configure the HART units ........................................................................................66
5.9
Configure Meter corrections ............................................................................ 66
5.9.1
Flow profile correction.............................................................................................66
5.9.2
Temperature expansion correction..........................................................................66
5.9.3
Pressure expansion correction .................................................................................66
5.10
Configure Temperature and Pressure .............................................................. 67
5.10.1
Flow-condition pressure and temperature .............................................................67
5.10.2
Configure the temperature parameters for the meter ...........................................69
5.10.3
Configure the pressure parameters for the meter. .................................................69
5.11
Configure Gas Chromatograph parameters ...................................................... 70
5.11.1
Gas properties .......................................................................................................71