background image

  WOP-2ac-LR5. User manual

24












4.4.6  The 'Network Information' submenu

In the 'Network Information' submenu common network settings of the device can be viewed.

WAN Status:

Interface –

 name of the bridge interface;

Protocol

 – a protocol used to access the WAN;

IP address

 – device IP address in external network;

RX Bytes

 – number of bytes received on WAN;

TX Bytes

 – number of bytes sent from WAN;

Ethernet:

Link Status

 – Ethernet port status;

Speed

 – Ethernet port connection speed;

Duplex

 – data transfer mode:

Full

 – full duplex;

Half

 – half duplex.

SFP

SFP-module Status

 – indicates presence/absence of SFP module;

Link Status

 – optical interface operation status;

Tx Fault

 – transceiver failure indication;

LOS

 – signal loss;

Speed

 – data transfer rate;

Содержание WOP-2ac-LR5

Страница 1: ...IP address 192 168 1 10 Username admin Password password Base station WOP 2ac LR5 User Manual Firmware version 1 5 0 ...

Страница 2: ...f 5 GHz and 6 GHz for Wi Fi 12 3 3 WOP 2ac LR5 mounting 13 4 Managing the device through WEB interface 15 4 1 Getting started 15 4 2 Applying configuration and discarding changes 16 4 3 Main Elements of the web Interface 17 4 4 The Monitoring menu 18 4 4 1 The Wi Fi Clients submenu 18 4 4 2 The WDS submenu 20 4 4 3 The Traffic Statistics submenu 21 4 4 4 The Scan Environment submenu 22 4 4 5 The E...

Страница 3: ... submenu 34 4 8 2 The Access submenu 35 4 9 The System menu 37 4 9 1 The Device Firmware Upgrade submenu 37 4 9 2 The Configuration submenu 38 4 9 3 The Reboot submenu 39 4 9 4 The Password submenu 39 4 9 5 The Log submenu 40 4 9 6 The Date and Time submenu 40 5 Spectrum Analyzer 42 6 System recovering after firmware update failure 43 7 The list of changes 44 ...

Страница 4: ...eless Internet access in the range of up to 3 km and Triple Play services The device is a good choice for wireless network construction in any climatic conditions in a wide operating temperature range and in high humidity The device allows connecting different sectoral antennas This manual specifies intended purpose main technical parameters design installation procedure and instructions for confi...

Страница 5: ... 100 1000Base X SFP 2 SMA female connectors for external antennas The choice of a model depends on the intended use of the access point for wireless bridges it is preferable to choose narrow band antennas and in the base station mode sectoral antennas with a wider directional pattern are should be chosen Wi Fi 5 6 GHz IEEE 802 11a n ac The power is supplied via a PoE injector IEEE 802 3at 2009 Fun...

Страница 6: ...Fig 1 shows an operation diagram for WOP 2ac LR5 Fig 1 WOP 2ac LR5 operation diagram 2 3 Technical Features Table 1 shows main specifications of the device Table 1 Main specifications Ethernet interface parameters Number of ports 1 Electrical connector RJ 45 SFP Data rate Mbps 10 100 1000 auto negotiation Standards BASE T BASE X Port features Combo port ...

Страница 7: ...P 2ac LR5 28 dBm for WOP 2ac LR5 rev B Receiver sensitivity 5 6 GHz up to 94 dBm Security 64 128 152 bit WEP encryption WPA WPA2 centralized authorization via RADIUS server WPA WPA2 Enterprise Control Remote control Web interface CLI Telnet SSH SNMP monitoring NETCONF Access restriction by password General parameters Processor Realtek RTL8197FS 1 GHz RAM 128 MB Flash 32 MB Power supply PoE IEEE 80...

Страница 8: ...g to IEEE 802 11n ac standards The real bandwidth will be different Conditions under which a network operates environmental factors including a volume of network traffic network service data building materials and constructions might decrease the real bandwidth Environmental factors might also influence a network coverage range 2 The number of channels and the value of the maximum output power wil...

Страница 9: ... LR5 is shown in the Fig 2 Fig 2 WOP 2ac LR5 A combo port 10 100 1000Base T Ethernet 100 1000Base X SFP for local network connection and power supply via PoE a grounding terminal for WOP 2ac LR5 H W version 1v5 and higher for WOP 2ac LR5 rev B and a factory reset button F are located under the cover at the bottom of the device Fig 3 Fig 3 WOP 2ac LR5 ports ...

Страница 10: ...the table 2 Table 2 Description of indicators Indicator Indicator status Description Power power and operation status indicator solid green power supply is connected normal operation solid orange IP address has not been received via DHCP solid red the device is loading LAN Ethernet interface port indicator solid green 10 100 Mbps solid orange 1000 Mbps the channel between Ethernet interface of WOP...

Страница 11: ...e device is loaded press and hold the F button located on the bottom panel approximately 10 15 seconds until the Power indicator is flashing orange Device will be rebooted automatically DHCP client will be launched by default If the address is not received via DHCP the device will have IP address 192 168 1 10 subnet mask 255 255 255 0 Username Password to access via web interface admin password 2 ...

Страница 12: ...e device check it for visible mechanical defects In case of mechanical damage you should stop the device installation draw up a corresponding report and contact the supplier Install the device on communications mast or pole in the way that the Ethernet port is pointed down During the device installation take into account the following rules to provide Wi Fi coverage area with the best characterist...

Страница 13: ... provided as shown in the figure below Install the device on communications mast pole with Ethernet port down as it is shown in the figure below Attach the device using clamps supplied in the device package Follow the safety rules and recommendations given in Safety rules and Installation recommendations ...

Страница 14: ...e the bottom cover Connect the antenna to the device using the cable assemblies Adjust the position of the antenna so that subscriber devices fall into the coverage area of the installed antenna Connect the Ethernet cable coming from WOP 2ac LR5 to the PoE port or the injector or switch IEEE 802 3at 2009 If you use a PoE injector connect it to 220 V power supply network using the cable Adjust the ...

Страница 15: ...quest form with user name and password will be displayed in a browser window 3 Enter your username into Login and password into Password field 4 Click the Log in button Device Web configurator home page will be opened in the browser window 5 If necessary you can switch the display language Russin and English languages are available for WOP 2ac LR5 IP address by default 192 168 1 10 subnet mask 255...

Страница 16: ...is indicated by the icon in the tab name and on the Apply button Successful settings saving and application are indicated by icon in the tab name 2 Discarding changes The button for discarding changes appears as follows Click the button to save the configuration into the device flash memory and apply new settings All the settings come into operation without device rebooting You can discard changes...

Страница 17: ...o five general areas Menu tabs categorize the submenu tabs Monitoring Radio VAP WDS Network settings System Interface language selection and Logout button designed to to end a session in the web interface under a given user Submenu tabs allows controlling the settings field Device configuration field displays data and configuration Information field displays current firmware version ...

Страница 18: ...r the last 10 s Link Quality parameter that displays the status of the link to the client calculated based on the number of retransmit packets sent to the client The maximum value is 100 all transmitted packets were sent on the first attempt the minimum value is 0 no packets were successfully sent to the client The parameter value is calculated for the last 10 s Link Quality Common parameter that ...

Страница 19: ...he number of packets sent with errors to the connected device TX Period Retry packets the number of retransmissions to the connected device in the last 10 s TX Retry Count packets the number of retransmissions to the connected device during all the time of connection Actual TX RX Rate Kbps the current traffic transmission rate ...

Страница 20: ...client calculated based on the number of retransmit packets sent to the client The maximum value is 100 all transmitted packets were sent on the first attempt the minimum value is 0 no packets were successfully sent to the client The parameter value is calculated for the last 10 s Link Quality Common parameter that displays the status of the link to the client calculated based on the number of ret...

Страница 21: ...st minute as well as statistics on the amount of transmitted received traffic since the access point was turned on The LAN Tx Rx diagram shows the speed of the traffic transmitted received via the access point s Ethernet interface in the last minute The The diagram is automatically updated every 2 seconds The WLAN Tx Rx diagram shows the speed of the traffic transmitted received via the access poi...

Страница 22: ...icking on the Scan button the process will be launched After the scan is completed a list of detected access points and information about them will appear SSID SSID of the detected access point Security security mode of the detected access point MAC MAC address of the detected access point Channel Bandwidth radio channel on which the detected access point operates RSSI the level with which the dev...

Страница 23: ...e event description Level Message importance level Description 0 Emergency A critical error has occurred in the system the system can go wrong 1 Alert Immediate intervention in the system is required 2 Critical A critical error has occurred in the system 3 Error An error has occurred in the system 4 Warning Warning non emergency message 5 Notice System notice non emergency message 6 Informational ...

Страница 24: ...ress device IP address in external network RX Bytes number of bytes received on WAN TX Bytes number of bytes sent from WAN Ethernet Link Status Ethernet port status Speed Ethernet port connection speed Duplex data transfer mode Full full duplex Half half duplex SFP SFP module Status indicates presence absence of SFP module Link Status optical interface operation status Tx Fault transceiver failure...

Страница 25: ...t connection networks R indicates that the route was most likely created by a dynamic routing protocol running on the local system using the reinstate parameter D indicates that the route was added as a result of receiving an ICMP Redirect Message When the system learns the route from the ICMP Redirect message the route will be added into the routing table in order to prevent redirection of the fo...

Страница 26: ...on Factory MAC Address device WAN interface MAC address set by the manufacturer Serial Number device serial number set by manufacturer Firmware Version device firmware version Backup Version previously installed firmware version Boot Version device bootloader firmware version System Time current time and date set in system Uptime the time since the last time the device was turned on or restarted ...

Страница 27: ...on Fixed center frequency when the flag is checked all traffic data and management packets will be transmitted at the specified channel center frequency with a given bandwidth 40 or 80 MHz The function is proprietary transmission is not carried out according to IEEE 802 11 standards where it is supposed to use different center frequencies for data and management traffic with 40 80 MHz bandwidth Tx...

Страница 28: ...prove data transmission reliability The field is available only if the selected mode of radio interface operation includes 802 11n When checked the device transmits one data flow through several antennas When unchecked the device does not transmit one data flow through several antennas Beacon Interval ms beacon frames transmission period The frames are sent to detect access points The parameter ta...

Страница 29: ...o 802 1p cs6 cs7 priorities AIFS Arbitration Inter Frame Spacing defines the waiting time of data frames measured in slots takes values 1 255 cwMin the initial timeout value before resending a frame specified in milliseconds takes the values 1 3 7 15 31 63 127 255 511 1023 The value of cwMin cannot exceed the value of cwMax cwMax the maximum timeout value before resending a frame specified in mill...

Страница 30: ...ic frоm clients will be tagged with VLAN ID when VLAN Trunk mode is disabled SSID virtual wireless network name Broadcast SSID when checked SSID broadcasting is on otherwise it is disabled VLAN Trunk when the flag is set tagged traffic is transmitted to the subscriber General Mode when the flag is set transmission of untagged traffic jointly with tagged traffic is allowed available when Trunk VLAN...

Страница 31: ...l pass to the client without a tag When traffic passes in the opposite direction untagged traffic will be tagged with General VLAN ID Station Isolation when checked traffic isolation between clients on the same VAP is enabled Maximum Stations the maximum number of clients connected to the virtual network Security wireless access security mode Off do not use encryption for data transfer The access ...

Страница 32: ...ccounting Use Periodic Accounting enable periodic sending of Accounting messages to the RADIUS server You can set the interval for sending messages in the Accounting Interval field Shapers Show display configuration field VAP Limit Down restriction of bandwidth in the direction from the access point to the clients in total connected to the VAP Kbps VAP Limit Up restriction of bandwidth in the dire...

Страница 33: ...ting is available WPA Key key password required to connect to the virtual access point The key length is from 8 to 63 characters Link X where X 0 7 enable wireless bridge link MAC MAC address of the opposite device to which the wireless bridge is configured Fixed Transmit Rate fixed wireless data transmission rate which defined by IEEE 802 11a n ac standards and selected individually for each link...

Страница 34: ...l that will be used to connect the device to service provider network via Ethernet interface DHCP operation mode where IP address subnet mask DNS server address defualt gateway and other parameters required for operation are obtained from DHCP server automatically Static operation mode where IP address and all the necessary parameters for WAN interface are assigned statically If Static is selected...

Страница 35: ...ice via Telnet select the checkbox in front of Telnet To enable access to the device via SSH select the checkbox in front of SSH To enable access to the device via NETCONF select the checkbox in front of NETCONF WOP 2ac LR5 software allows device status and sensors monitoring via SNMP In the SNMP submenu SNMP agent can be configured The device has support for SNMPv1 SNMPv2 To change the SNMP setti...

Страница 36: ...on Trap community password contained in traps default value trap The list of objects available for reading and configuring via SNMP is given below eltexLtd 1 127 1 monitoring of BS parameters and connected APs eltexLtd 1 127 3 BS management reboot where eltexLtd 1 3 6 1 4 1 35265 is Eltex Enterprise identifier To apply a new configuration and save settings to non volatile memory click Apply Click ...

Страница 37: ...e firmware file from http eltex co com support downloads and save it to your computer To do this click the Choose file button in the Firmware Image field and specify the path to the firmware file in tar gz format To start the update process click the Start Upgrading button The process may take several minutes its current status will be shown on the page The device will be automatically rebooted wh...

Страница 38: ...hange the passwords open the configuration file in text editor and edit them Then save the changes in configuration archive The example of password changing is shown below authentication admin password encrypted 7068747570617169 changes to authentication admin password password Reset to Default Configuration To reset all the settings to default values click Reset button If the checkbox Save access...

Страница 39: ... 9 4 The Password submenu When logging in via WEB interface administrator default password password has the full access to the device read write access to any settings full device status monitoring To change a password enter a new one first in the Password field and then in the Confirm Password field Click the Apply button to save a new password ...

Страница 40: ...ncoming Syslog server messages default 514 valid values from 1 to 65535 File Size KiB maximum size of the log file valid values 1 1000 kB 4 9 6 The Date and Time submenu In the Date and Time submenu you can set the time manually or using the time synchronization protocol NTP Manual Date and Time device date and time set on the device Click the Edit button if the correction is necessary Date Time s...

Страница 41: ...NTP Server Date and Time device date and time set on the device NTP Server time synchronization server IP address domain name You can specify an address or select from the list Time Zone allows to set the timezone according to the nearest city for your region from the list To apply a new configuration and save settings to the non volatile memory click the Apply button To discard changes click the ...

Страница 42: ...proximately 5 minutes As a result of the spectrum analyzer operation load information for each channel in percent will be displayed in the console WOP 2ac LR5 root monitoring spectrum analyzer Channel CCA 36 4 37 3 38 1 39 5 40 3 41 5 42 1 43 6 44 4 45 3 46 1 47 4 48 4 49 4 Please note that all clients will be disconnected from the base station during spectrum analyzer operation The client station...

Страница 43: ... the unzipped firmware archive for transferring Run the command to send a file to the remote host the Put command The process of file transmission will be launched If transmission process has been started please wait for its finishing The device will write the firmware to its memory and launch the system automatically Writing takes approximately 8 minutes If the process is completed successfully t...

Страница 44: ...are version 1 4 2 Version 1 2 11 12 2019 Synchronization with firmware version 1 4 1 Version 1 1 06 11 2019 Synchronization with firmware version 1 4 0 Changes in sections 2 4 Design 3 3 WOP 2ac LR5 Mounting 4 4 5 Events 4 5 1 Radio 4 5 2 QoS 4 6 VAP 4 7 WDS 4 8 1 System configuration 4 8 2 Access 4 9 1 Device Firmware Upgrade 4 9 6 Date and Time 5 Spectrum Analyzer Chapters added 4 9 5 Log Versio...

Страница 45: ...sibirsk Russian Federation 630020 E mail techsupp eltex co ru You are welcome to visit ELTEX official website to get the relevant technical documentation and software for ELTEX products or consult a Service Center Specialist on our technical forum https eltex co com https eltex co com support downloads http forum eltex co ru ...

Отзывы: