20
SBC session border controllers
solid yellow
warnings
Stream remote alarm
Synchronization from the lower priority source (the one with the higher
priority is not available)
FTP server unavailable, CDR file storage RAM is full up to 5 MB
Redundant: slave has another firmware version
2.6
'F' Function Button Operation
The F button allows you to reboot the device, restore the factory configuration and to reset the password.
For resetting to factory settings when the device is switched on, see Tables 13 and 14 in Section 2.5.3.
When the factory configuration is restored, you can access the device by IP address 192.168.1.2 (mask
255.255.255.0):
–
via Telnet/SSH or console with login
admin
, password
rootpasswd
;
–
via web interface with login
admin
, password
rootpasswd
;
Next, you may save the factory configuration, restore password or reboot the device.
2.7
Saving factory configuration
To save the factory configuration:
–
reset the device to factory settings (Section 2.5.3);
–
connect via telnet or console with login
admin
, password
rootpasswd
;
–
Enter the
sh
command (the device will exit the CLI mode and enter the SHELL mode);
–
enter the
save
command;
–
reboot the device using the
reboot
command.
The gateway will be restarted with the factory configuration.
*********************************************
* Welcome to SBC-1000 *
*********************************************
smg login:
admin
Password:
rootpasswd
********************************************
* Welcome to SBC-1000 *
********************************************
Welcome! It is Wed Mar 11 08:45:20 NOVT 2015
SBC> sh
/home/admin #
save
tar: removing leading '/' from member names
**********
**********
***Saved successful
New image 1
Restored successful
/home/admin #
reboot