154
MES1000, MES2000 Ethernet Switches
If the controlling port has already been configured,
you can use only that port for VLAN monitoring.
no port monitor vlan
vlan_id
Remove the specified VLAN from the monitoring.
port monitor remote
-
Enable remote monitoring function for the configured
interface.
no port monitor remote
Disable remote monitoring function for the configured
interface.
EXEC mode commands
Command line request in EXEC mode appears as follows:
console>
Table 5.173 —Commands available in EXEC mode
Command
Action
show ports monitor
Show information on monitored and controlling ports.
Example execution of commands
Define Ethernet interface 13 as the controlling interface for Ethernet interface 18. Transfer all
traffic from the interface 18 to the interface 13.
console#
configure
console(config)#
interface gigabitethernet
1/0/13
console(config-if)#
port monitor
gigabitethernet
1/0/18
Show information on monitored and controlling ports.
console#
show ports monitor
Source Port Destination Port Type Status
----------- ---------------- ------- ----------