Settings on the device
Ultrasonic Probe KNX SO250
• Version: 14.09.2020 • Technical changes and errors excepted.
Tank drainage:
Overfill warning:
Empty warning:
4.4.2. Relay 1 / 2 for fault warning
Confirm your selection with the key . You will automatically return to the basic sta
-
tus.
The selected relay now closes in the event of a fault, further settings are not possible.
To switch off the fault message, select a function for the relay in the "R 1/2 settings"
menu item.
Start tank drainage
with R 1 when
a maximum level of
90% is reached.
Use the keys
and
to set the maximum level
(in %) at which the emptying of the tank is started.
Confirm your setting with the key .
Stop tank drainage
with R 1 when
a minimum level of
15% is reached.
Use the keys
and
to set the minimum level
(in %) at which the emptying of the tank stops.
Confirm your setting with the key . You will au
-
tomatically return to the initial position.
Warn "Tank is full"
with R 1 when
a maximum level of
90% is reached.
Use the keys
and
to set the maximum level
(in %) from which an overflow message is output.
Confirm your setting with the key . You will au
-
tomatically return to the basic status.
Warn "Tank is empty"
with R 1 when
a minimum level of
15% is reached.
Use the keys
and
to set the minimum level
(in %) from which an empty message is output.
Confirm your setting with the key . You will au
-
tomatically return to the basic status.
R 1 settings
>™
R 2 settings
>
R 1 fault warning
>
R 2 fault warning
>
If you want to output a fault warning via the relay,
use the keys
or
to move the cursor to the
menu item "R 1 Fault warning" or "R 2 Fault warn
-
ing".