Description of the menu options
ELSA LANCOM Business
R81
Table firmsafe
This table provides the following details for the two firmware versions stored in the
device: the position in memory (1 or 2), status information (active or inactive), the version
number, the date, the size and the index (sequential number).
Enter the following command to activate an inactive firmware version:
set <position number> active.
Mode-firmsafe
Only one of the firmware versions stored in the device can be active at any one time.
When new firmware is loaded the inactive firmware is overwritten. You can decide
which firmware will be activated after the upload:
쮿
'immediate': The first option is to load the new firmware and activate it
immediately. The following situations can result:
– The new firmware is successfully loaded and then operates as desired.
Everything is then in order.
– However, if the new firmware does not operate correctly, it may not be possible
to communicate with the device after the restart. If an error occurs during the
upload, the device automatically reactivates the previous firmware version and
reboots the device.
쮿
'login': To prevent problems caused by defective firmware, the second option will
load the firmware and start it immediately.
– In contrast to the first option, the firmsafe will wait until it has successfully
logged on over outband or inband (by telnet). In contrast to the first option, the
firmsafe will wait until it has successfully logged on (by telnet). The new
firmware will only be permanently activated when the login occurs successfully
within the time set under 'Timeout firmsafe'.
– If the device no longer responds and it is therefore impossible to log in, the
firmware automatically loads the previous firmware version and reboots the
device with it.
쮿
'manual': The third option allows you to set a period (Timeout firmsafe) beforehand
for testing the new firmware. The device will start with the new firmware and wait
for the preset period until the loaded firmware is manually activated and therefore
becomes permanently effective.
Position
Status
Version
Date
Size
Index
1
Inactive
1.60
23061999
690
6
2
Active
1.60
30061999
692
7
3
<loader>
1.60
07061999
64
0
Содержание LANCOM Business LC-4X00
Страница 1: ...Manual ELSA LANCOM TM Business No 20857 0999...
Страница 4: ......
Страница 10: ...Content ELSA LANCOM Business X...
Страница 22: ...Introduction ELSA LANCOM Business 12...
Страница 42: ...Configuration modes ELSA LANCOM Business 32...
Страница 112: ...Operating modes and functions ELSA LANCOM Business 102...
Страница 146: ...Workshop ELSA LANCOM Business 136...
Страница 152: ...Appendix ELSA LANCOM Business 142...
Страница 160: ...Glossary ELSA LANCOM Business 150...
Страница 170: ...Index ELSA LANCOM Business 160...
Страница 259: ...TCP IP ports ELSA LANCOM Business R89 rscsb 10011 udp qmaster 10012 tcp qmaster 10012 udp Capab Port no Protocol...
Страница 260: ...TCP IP ports ELSA LANCOM Business R90...