Description of the menu options
ELSA LANCOM Business
R47
쮿
Device name: Name of the logical remote station
쮿
Script: All commands to be executed—a maximum of 58 characters per line is
available. If the required command sequence is longer, an additional entry for the
logical remote station may be added as in the round-robin list. The syntax for this
is: Device name followed by '#' and a number. The entries are processed from top
to bottom.
Setup/WAN-module/Manual-dialing
This option can be used for manual connection control for testing purposes.
Connect
Parameter: Remote station’s device name (via remote configuration only).
You can use the command
Do /Setup/WAN-module/Manual-dialing/Connect to remote
station
to initiate the manual establishment of a connection via remote configuration. The
remote station’s device name specified as a parameter must also be entered in the name
list with a call number.
When the function is activated by the keyboard of the
ELSA LANCOM, the error message
'No remote station' is displayed, because a name cannot be entered here. Therefore, this
function must not be used from the keyboard of the
ELSA LANCOM. If you attempt to
establish a connection to a logical remote station for which no call number is specified
in the name list, the 'No number' error message is displayed.
Disconnect
This command allows you to release an existing connection. If a connection is released
manually, the name of a remote station may also be entered in the remote configuration.
In this case, only the connection to the remote station specified is released. If a
connection to the remote station specified does not exist, there is no further response.
However, if a remote station name is not entered, all existing connections will be
released.
Setup/WAN-module/protection
This option allows you to select the conditions under which incoming calls are to be
answered at the transmission module.
쮿
If 'Protect' is set to 'none', all pending calls are answered provided that the remote
end supports the connection protocol.
/Manual-dialing
Settings for manual connection control
Connect
Establishes a connection.
Disconnect
Termination of connections
State
Displays the current connection status.
Содержание LANCOM Business LC-4X00
Страница 1: ...Manual ELSA LANCOM TM Business No 20857 0999...
Страница 4: ......
Страница 10: ...Content ELSA LANCOM Business X...
Страница 22: ...Introduction ELSA LANCOM Business 12...
Страница 42: ...Configuration modes ELSA LANCOM Business 32...
Страница 112: ...Operating modes and functions ELSA LANCOM Business 102...
Страница 146: ...Workshop ELSA LANCOM Business 136...
Страница 152: ...Appendix ELSA LANCOM Business 142...
Страница 160: ...Glossary ELSA LANCOM Business 150...
Страница 170: ...Index ELSA LANCOM Business 160...
Страница 259: ...TCP IP ports ELSA LANCOM Business R89 rscsb 10011 udp qmaster 10012 tcp qmaster 10012 udp Capab Port no Protocol...
Страница 260: ...TCP IP ports ELSA LANCOM Business R90...