Description of the menu options
ELSA LANCOM Business
R75
LAN-config
This option allows you to define whether remote configuration from the LAN side is
possible (
On
), is not possible (
Off
), or is possible only in read mode (
Read
). The default
setting for this option is
On
.
WAN-config
This option allows you to define whether remote configuration from the WAN side is
possible (
On
), is not possible (
Off
), or is possible only in read mode (
Read
). The default
setting for this option is
Off
.
Password-
required
This specifies whether a new password should be requested every time a remote
configuration is begun (
On
), or the password request should be suppressed (
Off
). The
default setting for this option is
On
.
Farconfig-(EAZ-
MSN)
This subscriber number permits remote configuration via PPP. If no number is specified
here, remote-configuration calls will be accepted on all numbers.
Maximum
connections
This option allows you to display the maximum number of remote configuration sessions
that can occur simultaneously for the device.
Config-aging-
minute(s)
If data transmission halts during a remote configuration session, e.g. because the user is
no longer entering data, the device automatically releases the connection at the end of
the time period specified here. Possible settings are from 1 to 99 minutes; the default
setting is 5 minutes.
Login-errors
This entry specifies the number of failed attempts allowed before the log-in block is
activated. An empty password (simply pressing <ENTER> at the password prompt) is not
considered an attempt and therefore does not activate the block.
The default value is 5. A lower value may cause the log-in block to be activated with only
one access on an older ELSA LANconfig! In this case obtain an updated ELSA LANconfig
version over our online media.
Lock-minutes
This entry has two meanings. It indicates how long the access is blocked if the log-in
block has been activated. It also sets the period after which the device forgets all prior
login errors.
Language
This option allows you to select whether you will use the German or English version of
the software for performing the configuration.
Config-aging-minute(s)
Time limit for remote configuration connections
Login-errors
Number for failed log-in attempts before the log-in block is
activated
Lock-minutes
Duration of block and period until old log-in errors are for-
gotten
Display contrast
Language
Configuration language
/Config-module
Configuration module settings
Содержание LANCOM Business LC-4X00
Страница 1: ...Manual ELSA LANCOM TM Business No 20857 0999...
Страница 4: ......
Страница 10: ...Content ELSA LANCOM Business X...
Страница 22: ...Introduction ELSA LANCOM Business 12...
Страница 42: ...Configuration modes ELSA LANCOM Business 32...
Страница 112: ...Operating modes and functions ELSA LANCOM Business 102...
Страница 146: ...Workshop ELSA LANCOM Business 136...
Страница 152: ...Appendix ELSA LANCOM Business 142...
Страница 160: ...Glossary ELSA LANCOM Business 150...
Страница 170: ...Index ELSA LANCOM Business 160...
Страница 259: ...TCP IP ports ELSA LANCOM Business R89 rscsb 10011 udp qmaster 10012 tcp qmaster 10012 udp Capab Port no Protocol...
Страница 260: ...TCP IP ports ELSA LANCOM Business R90...