44
3.
Unit will indicate starting process by short flash of all four input LEDs and then progress of
writing file with input LED scan through 1 to 4. DO NOT REMOVE USB stick during writing
process.
4.
Completion is indicated by all four input LEDs with come on and go out.
General Specifications
Operation
Modes-Topology
Field, Repeater and Receiver station unit types
Input and Output
Discrete input/output
4 digital I/O (discrete/pulsed, rain or river encoder)
On-state voltage: <1 Vdc
Off-state voltage: >2 Vdc
Wetting current: 30µA
Minimum input pulse width 1ms (active input)
Analog Inputs
2 single ended analog inputs configurable mA
0-20mA current loop (under/over range)
16 bits resolution
Impedance < 10
0Ω
Sensor Loop Power
Analog: 24Vdc, max 50mA
SDI-12: 12Vdc, max 500mA
SDI-12 (v1.4)
1 loop: max of 52 configurable variables or sensors
M or R command and CRC configurable
Data Rate: 1200 bps, 7 data, 1 parity
Heater Output
Open Collector output (active close to ground) available to allow
internal heating in very cold environments. ON @ -10
o
C OFF @
0
o
C, 2A max
GPS (Optional)
Time clock synchronization for logging/ALERT2
GPS antenna: SMA Female (LNA power)
Protocols and Configuration
User configuration
Secure, user friendly, device agnostic, menu-based
Remote (over-the-air) access: Bluetooth BLE
Local Access: USB or RS232 (legacy)
Configurable
Parameters
ALERT1 (field station, receiver only),
ALERT2™,
field/repeater/receiver station, communications setup, unit ID,
reporting times, input configuration, analog loop power warmup,
date/time, SDI sensor power, logging
RS-485 (Future)
Note 3
ALERT1 input (Repeater only, ALERT2 Consolidation mode)
ALERT2 output (Base Receiver output to decoder)
ALERT2 redundancy (Repeater Gateway)
Configurable 300-115200 baud/ parity/ stop
LED Indications & Diagnostics
LED Indication
Power/OK, Radio TX/RX, Config Enabled, Maintenance Mode
Push Buttons
Front Panel: Maintenance mode/Send data
Internal Test: Maintenance mode/send data/save logged data to
USB/Firmware update
Internal Boot: Boot or Reset unit (IO values preserved)
Reported Values