River (Analog)
Externally Powered devices can be connected directly
to the AIN+ & AIN- connection pins.
If connecting to a single ended device, then the module
can provide the +24V Loop supply and will need to be
connected as per the diagram.
Solar (Ext Supply)
The Solar connector allows for the connection of a 5-30W
solar panel connection or an external 24W power supply to
power or charge the internal / external battery.
Warning: The solar input is suitable for solar panels rated
as 12V nominal only. 24V solar panel can produce open
circuit voltages of 44Vdc which will exceed the rated input
of the solar regulator and cause damage.